Sba: Controle & Automação Sociedade Brasileira de Automatica2005
A line-interactive UPS system implementation with series-parallel active power-line conditioning for three-phase, four-wire systems
Sérgio Augusto Oliveira da Silva, Pedro F. Donoso-Garcia, Porfírio C. Cortizo e Paulo F. Seixas
em inglês
resumo
This paper presents a three-phase line-interactive uninterruptible power supply (UPS) system with active series-parallel power-line conditioning capabilities. Synchronous reference frame (SRF)-based controller is used for harmonic and reactive power compensation generated from any configuration of non-linear loads. Under normal line conditions the UPS system works with universal filtering capabilities, such as compensating the input currents and output voltages. Two three-phase pulsewidth modulation (PWM) converters, called series and parallel active filters, are used to perform the series and parallel active power-line compensation. The series active filter works as sinusoidal current source in phase with the input voltage, drawing from utility sinusoidal and balanced input currents with low total harmonic distortion (THD). The parallel active filter works as sinusoidal voltage source in phase with the input voltage, providing regulated and sinusoidal output voltages with low THD. The performance of the UPS system is evaluated in three-phase, four-wire systems. Experimental results are presented to confirm the theoretical studies.
como citar · ABNT NBR 6023
SILVA, Sérgio Augusto Oliveira da et al. A line-interactive UPS system implementation with series-parallel active power-line conditioning for three-phase, four-wire systems. Sba: Controle & Automação Sociedade Brasileira de Automatica, 2005. DOI: 10.1590/S0103-17592005000200008.
Referências
9 obras citadas
- 1T. M. Gruzs. A Survey of Neutral Currents in Three-Phase Computer Power Systems. IEEE Transactions on Industry Applications, 1990quem mais cita →
- 2C. A. Quinn e N. Mohan. Active Filtering of Harmonic Currents in Three-Phase, Four-Wire Systems with Three-Phase and Single-Phase Non-Linear Loads. Proceedings of the 7th Applied Power Electronics Conference and Exposition, 1992quem mais cita →
- 3C. A. Quinn, N. Mohan e H. Mehta. A Four-wire, Current-Controlled Converter Provides Harmonic Neutralization in Three-Phase, Four-Wire Systems. Proceedings of the 8th Applied Power Electronics Conference and Exposition, 1993quem mais cita →
- 4T. Thomas, K. Haddad, G. Joós e mais 1. Performance Evaluation of Three-Phase Three and Four Wire Active Filters. Proceedings of the 31th Industry Applications Society Annual Meeting, 1996quem mais cita →
- 5S. A. Oliveira da Silva, P. Donoso-Garcia, P. C. Cortizo e mais 1. A three-phase line-interactive UPS system implementation with series-parallel active power-line conditioning capabilities. Proceedings of the 36th Industry Applications Society Annual Meeting, 2001quem mais cita →
- 6F. Kamran e T. Habtler. A Novel On-Line UPS with Universal Filtering Capabilities. Proceedings of the 26th Power Electronics Specialist Conference, 1995quem mais cita →
- 7S. J. Jeon e G. H. Cho. A Series-Parallel Compensated Uninterruptible Power Supply with Sinusoidal Input Current and Sinusoidal Output Voltage. Proceedings of the 28th Power Electronics Specialist Conference, 1997quem mais cita →
- 8R. Cheung, L. Cheng, P. Yu e mais 1. New Line-Interactive UPS System with DSP-Based Active Power-Line Conditioning. Proceedings of the 27th Power Electronics Specialist Conference, 1996quem mais cita →
- 9Y. Lin, G. Joos e J. F Lindsay. Performance Analysis of Parallel-Processing UPS Systems. Proceedings of the 8th Applied Power Electronics Conference and Exposition, 1993quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda