Acta Cirúrgica Brasileira2003

Experimental model in rat for sentinel node biopsy

Renato Santos de Oliveira Filho, Geruza Rezende Paiva, Jairo Wagner e Solange Amorim Nogueira

em inglês

cita 12 obras, 1 no acervo

resumo

Although sentinel node procedure has been used world wide, there are many aspects to be defined and better standardized. This study address if the experimental model in rats is appropriate for sentinel node biopsy. In this model, the lymph nodes are showed by lymphoscintigraphy, they are dyed by patent blue and identified by intraoperative gamma probe detection. It isn’t necessary to use magnification for the procedure. The model demonstrated that sentinel node biopsy in rats is feasible. So, besides allowing researches in this field, the model is useful for training and diffusing this technique.

como citar · ABNT NBR 6023

OLIVEIRA FILHO, Renato Santos de et al. Experimental model in rat for sentinel node biopsy. Acta Cirúrgica Brasileira, 2003. DOI: 10.1590/S0102-86502003001100003.

Referências

12 obras citadas · 1 no acervo

  1. 1CM Balch, AC Buzaid, SJ Soong e mais 3. Final Version of the American Joint Committee on Cancer Staging System for Cutaneous Melanoma. Journal of Clinical Oncology, 2001quem mais cita →
  2. 2RS Oliveira-Filho, LM Ferreira, CM Eto e mais 2. Biópsia de linfonodo sentinela no melanoma cutâneo. Melanoma Cutâneo Localizado e Linfonodo Sentinela, 2003quem mais cita →
  3. 3Dl Morton, Jf Thompson e R Esser. Validation of the accuracy of intraoperative lymphatic mapping and sentinel Lymphadenectomy for early-stage melanoma. Arch Surg, 1992quem mais cita →
  4. 4R Pijipers, PJ Borgstein, S Meijer e mais 3. Sentinel biopsy in melanoma patients: Dynamic Lymphoscintigraphy followed by intraoperative Gamma Probe and Vital Dye Guidance. World J Surg, 1997quem mais cita →
  5. 5RS Oliveira Filho, ID Santos, LM Ferreira e mais 3. Is intra-operative gamma probe detection really necessary for inguinal sentinel lymph node biopsy?. São Paulo Med J, 2000no acervo →
  6. 6S Neubauer, I Mena, R Iglesis e mais 4. Sentinel lymph node mapping in melanoma with technetium-99m dextran. Cancer Biother Radiopharm, 2001quem mais cita →
  7. 7RS Oliveira-Filho, LM Ferreira e A Barbieri. Linfadenectomia seletiva com biópsia de linfonodo sentinela no melanoma cutâneo: Experiência brasileira. An bras Dermatol, 2000quem mais cita →
  8. 8MGM Tavares, MT Sapienza, NA Galeb e mais 3. The use of Tc99-Phytate for sentinel node mapping in melanoma, brest cancer and vulvar cancer: a study of 100 cases. Eur J Nucl Med, 2001quem mais cita →
  9. 9L Bergqvist, SE Strand e BRRR Persson. Particle sizing and biokinetics of intersticial lymphoscintigrapbic agents. Sem Nucl Med, 1983quem mais cita →
  10. 10LF Glass, JL Messina, W Cruse e mais 6. The use of Intraoperative Radiolymphoscintigraphy for Sentinel Node Biopsy in Patients with Malignant Melanoma. Dermatol Surg, 1996quem mais cita →
  11. 11M Kitajima. Universal application of sentinel node technology: Advent of the new era of individualized treatment of solid tumors.. 2002quem mais cita →
  12. 12HB Woynforth e PA Flecknell. Specific Surgical Operations. Experimental and Surgical Technique in the Rat, 1992quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações