Brazilian Journal of Cardiovascular Surgery2026
VDD Pacemaker Implantation Without Fluoroscopy for Complete Heart Block During Pregnancy: A Case Report
Roberto Tofani Sant’Anna, Tiago Luiz Luz Leiria, Marco Aurélio Lumertz Saffi, João Ricardo Michielin Sant’Anna e Gustavo Glotz De Lima
relato de caso · em inglês
resumo
ABSTRACT Ionizing radiation is associated with an increased risk of malignancy, especially in fetuses. Therefore, in the rare situation of a pregnant patient in need of a pacemaker, alternatives to conventional fluoroscopy are required. We describe a case of successful implantation of a Ventricle-paced, Dual-sensing, Dual-response pacemaker without fluoroscopy in a 32-year-old female patient using electroanatomic 3D mapping. She had severe bradycardia due to complete atrioventricular block, which impeded intrauterine growth restriction in the fetus.
como citar · ABNT NBR 6023
SANT’ANNA, Roberto Tofani et al. VDD Pacemaker Implantation Without Fluoroscopy for Complete Heart Block During Pregnancy: A Case Report. Brazilian Journal of Cardiovascular Surgery, 2026. DOI: 10.21470/1678-9741-2025-0290.
Referências
10 obras citadas
- 1R Doll e R. Wakeford. Risk of childhood cancer from fetal irradiation. Br J Radiol, 1997quem mais cita →
- 2R Thaman, S Curtis, G Faganello e mais 3. Cardiac outcome of pregnancy in women with a pacemaker and women with untreated atrioventricular conduction block. Europace, 2011quem mais cita →
- 3J Payne, M Lo, H Paydak e mais 1. Near-zero fluoroscopy implantation of dual-chamber pacemaker in pregnancy using electroanatomic mapping. HeartRhythm Case Rep, 2017quem mais cita →
- 4D Antonelli, L Bloch e T. Rosenfeld. Implantation of permanent dual chamber pacemaker in a pregnant woman by transesophageal echocardiographic guidance. Pacing Clin Electrophysiol, 1999quem mais cita →
- 5J Damilakis, N Theocharopoulos, K Perisinakis e mais 3. Conceptus radiation dose and risk from cardiac catheter ablation procedures. Circulation, 2001quem mais cita →
- 6M Alkhorayef, A Sulieman, E Babikir e mais 3. Patient exposure during fluoroscopy-guided pacemaker implantation procedures. Appl Radiat Isot, 2018quem mais cita →
- 7LM Pires, TLL Leiria, ML Kruse e mais 3. Catheter ablation of arrhythmias exclusively using electroanatomic mapping: a series of cases. Arq Bras Cardiol, 2013quem mais cita →
- 8LM Pires, TLL Leiria, ML Kruse e mais 1. Non-fluoroscopic catheter ablation: a randomized trial. Indian Pacing Electrophysiol J, 2019quem mais cita →
- 9M Shah, A Hashemi, F Afriyie e mais 3. The utility of leadless atrioventricular synchronous pacemaker implantation as a novel alternative to a traditional pacemaker during pregnancy. J Innov Card Rhythm Manag, 2023quem mais cita →
- 10YY Chua, JCK Tay, ETS Lim e mais 3. Impact of 3-dimensional electroanatomic mapping systems on fluoroscopy reduction in catheter ablation of supraventricular tachycardia - then and now. EP Europace, 2023quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda