Brazilian Journal of Cardiovascular Surgery2021

Early Hemodynamic Profile after Aortic Valve Replacement - A Comparison between Three Mechanical Valves

Khaled D. Algarni, Essam Hassan, Amr A. Arafat, Mostafa A. Shalaby, Hussein H. Elawad, Claudio Pragliola e Turki B. Albacker

em inglês

cita 11 obras

resumo

Abstract Introduction: There are scarce data comparing different mechanical valves in the aortic position. The objective of this study was to compare the early hemodynamic changes after aortic valve replacement between ATS, Bicarbon, and On-X mechanical valves. Methods: We included 99 patients who underwent aortic valve replacement with mechanical valves between 2017 and 2019. Three types of mechanical valves were used, On-X valve (n=45), ATS AP360 (n=32), and Bicarbon (n=22). The mean prosthetic valve gradient was measured postoperatively and after six months. Results: Preoperative data were comparable between groups, and there were no differences in preoperative echocardiographic data. Pre-discharge echocardiography showed no difference between groups in the ejection fraction (P=0.748), end-systolic (P=0.764) and end-diastolic (P=0.723) diameters, left ventricular mass index (P=0.348), aortic prosthetic mean pressure gradient (P=0.454), and indexed aortic prosthetic orifice area (P=0.576). There was no difference in the postoperative aortic prosthetic mean pressure gradient between groups when stratified by valve size. The changes in the aortic prosthetic mean pressure gradient of the intraoperative period, at pre-discharge, and at six months were comparable between the three prostheses (P=0.08). Multivariable regression analysis revealed that female gender (beta coefficient -0.242, P=0.027), body surface area (beta coefficient 0.334, P<0.001), and aortic prosthetic size (beta coefficient -0.547, P<0.001), but not the prosthesis type, were independent predictors of postoperative aortic prosthetic mean pressure gradient. Conclusion: The three bileaflet mechanical aortic prostheses (On-X, Bicarbon, and ATS) provide satisfactory early hemodynamics, which are comparable between the three valve types and among different valve sizes.

como citar · ABNT NBR 6023

ALGARNI, Khaled D. et al. Early Hemodynamic Profile after Aortic Valve Replacement - A Comparison between Three Mechanical Valves. Brazilian Journal of Cardiovascular Surgery, 2021. DOI: 10.21470/1678-9741-2020-0273.

Referências

11 obras citadas

  1. 1A Kheradvar, EM Groves, CJ Goergen e mais 3. Emerging trends in heart valve engineering: part II. Novel and standard technologies for aortic valve replacement. Ann Biomed Eng, 2015quem mais cita →
  2. 2H Lee, K Sung, WS Kim e mais 3. Late clinical outcomes after mechanical aortic valve replacement for aortic stenosis: old versus new prostheses. J Thorac Dis, 2018quem mais cita →
  3. 3H Baumgartner, V Falk, JJ Bax e mais 3. 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J, 2017quem mais cita →
  4. 4RA Nishimura, CM Otto, RO Bonow e mais 3. 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American college of cardiology/American heart association task force on clinical practice guidelines. Circulation, 2017quem mais cita →
  5. 5R Xu, M Rahnavardi, B Pitman e mais 3. On-X versus St Jude medical regent mechanical aortic valve prostheses: early haemodynamics. Open Heart, 2017quem mais cita →
  6. 6Y Misawa, A Muraoka, S Ohki e mais 3. Fifteen-year experience with the bicarbon heart valve prosthesis in a single center. J Cardiothorac Surg, 2015quem mais cita →
  7. 7WA Zoghbi, JB Chambers, JG Dumesnil e mais 3. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report from the American society of echocardiography's guidelines and standards committee and the task force on prosthetic valves, developed in conjunction with the American college of cardiology cardiovascular imaging committee, cardiac imaging committee of the American heart association, the European association of echocardiography, a registered branch of the European society of cardiology, the Japanese society of echocardiography and the Canadian society of echocardiography, endorsed by the American college of cardiology foundation, American heart association, European association of echocardiography, a registered branch of the European society of cardiology, the Japanese society of echocardiography, and Canadian society of Echocardiography. J Am Soc Echocardiogr, 2009quem mais cita →
  8. 8T Walther, V Falk, R Tigges e mais 3. Comparison of On-X and SJM HP bileaflet aortic valves. J Heart Valve Dis, 2000quem mais cita →
  9. 9PJ Tully, W Aty, GD Rice e mais 3. Aortic valve prosthesis-patient mismatch and long-term outcomes: 19-year single-center experience. Ann Thorac Surg, 2013quem mais cita →
  10. 10Y Kato, K Hattori, M Motoki e mais 3. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm). J Heart Valve Dis, 2013quem mais cita →
  11. 11JB Chambers, JL Pomar, CA Mestres e mais 1. Clinical event rates with the On-X bileaflet mechanical heart valve: a multicenter experience with follow-up to 12 years. J Thorac Cardiovasc Surg, 2013quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações