Brazilian Journal of Cardiovascular Surgery2017
Totally Percutaneous Access Using Perclose Proglide for Endovascular Treatment of Aortic Diseases
Eduardo Keller Saadi, Marina Saadi, Rodrigo Saadi, Ana Paula Tagliari e Bernardo Mastella
em inglês
citado por 1 artigocita 19 obras
resumo
Abstract Objective: To evaluate our experience following the introduction of a percutaneous program for endovascular treatment of aortic diseases using Perclose Proglide® assessing efficacy, complications and identification of potential risk factors that could predict failure or major access site complications. Methods: A retrospective cohort study during a two-year period was performed. All the patients submitted to totally percutaneous endovascular repair (PEVAR) of aortic diseases and transcatheter aortic valve implantation since we started the total percutaneous approach with the preclosure technique from November 2013 to December 2015 were included in the study. The primary endpoint was major ipsilateral access complication, defined according to PEVAR trial. Results: In a cohort of 123 patients, immediate technical success was obtained in 121 (98.37%) patients, with only two (0.82%) cases in 242 vascular access sites that required intervention immediately after the procedure. Pairwise comparisons revealed increased major access complication among patients with >50% common femoral artery (CFA) calcification vs. none (P=0.004) and > 50% CFA calcification vs. < 50% CFA calcification (P=0.002). Small artery diameter (<6.5 mm) also increased major access complication compared to bigger diameters (> 6.5 mm) (P=0.027). Conclusion: The preclosure technique with two Perclose Proglide® for PEVAR is safe and effective. Complications occur more often in patients with unfavorable access site anatomy and the success rate can be improved with proper patient selection.
como citar · ABNT NBR 6023
SAADI, Eduardo Keller et al. Totally Percutaneous Access Using Perclose Proglide for Endovascular Treatment of Aortic Diseases. Brazilian Journal of Cardiovascular Surgery, 2017. DOI: 10.21470/1678-9741-2016-0065.
Referências
19 obras citadas
- 1MR Patel, H Jneid, CP Derdeyn e mais 3. Arteriotomy closure devices for cardiovascular procedures a scientific statement from the American Heart Association. Circulation, 2010quem mais cita →
- 2PC Haas, Z Krajcer e EB Diethrich. Closure of large percutaneous access sites using the Prostar XL Percutaneous Vascular Surgery device. J Endovasc Surg, 1999quem mais cita →
- 3PR Nelson, Z Kracjer, N Kansal e mais 3. A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aortic aneurysm repair (the PEVAR trial). J Vasc Surg, 2014quem mais cita →
- 4DB Buck, EG Karthaus, PA Soden e mais 3. Percutaneous versus femoral cutdown access for endovascular aneurysm repair. J Vasc Surg, 2015quem mais cita →
- 5S Petronelli, MT Zurlo, S Giambersio e mais 2. A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR. Radiol Med, 2014quem mais cita →
- 6M Eisenack, T Umscheid, J Tessarek e mais 2. Percutaneous endovascular aortic aneurysm repair a prospective evaluation of safety, efficiency, and risk factors. J Endovasc Ther, 2009quem mais cita →
- 7WA Lee, MP Brown, PR Nelson e mais 2. Midterm outcomes of femoral arteries after percutaneous endovascular aortic repair using the Preclose technique. J Vasc Surg, 2008quem mais cita →
- 8AY Mousa, S Abu-Halimah, A Nanjundappa e mais 2. Current update on the status of totally percutaneous aneurysm repair. Vasc Endovascular Surg, 2013quem mais cita →
- 9RP Bensley, R Hurks, Z Huang e mais 3. Ultrasound-guided percutaneous endovascular aneurysm repair success is predicted by access vessel diameter. J Vasc Surg, 2012quem mais cita →
- 10AY Mousa, JE Campbell, M Broce e mais 3. Predictors of percutaneous access failure requiring open femoral surgical conversion during endovascular aortic aneurysm repair. J Vasc Surg, 2013quem mais cita →
- 11LG Teh, K Sieunarine, G van Schie e mais 3. Use of the percutaneous vascular surgery device for closure of femoral access sites during endovascular aneurysm repair lessons from our experience. Eur J Vasc Endovasc Surg, 2001quem mais cita →
- 12GS Georgiadis, GA Antoniou, M Papaioakim e mais 3. A meta-analysis of outcome after percutaneous endovascular aortic aneurysm repair using different size sheaths or endograft delivery systems. J Endovasc Ther, 2011quem mais cita →
- 13P Kahlert, H Eggebrecht, R Erbel e mais 1. A modified "preclosure" technique after percutaneous aortic valve replacement. Catheter Cardiovasc Interv, 2008quem mais cita →
- 14J Zakko, S Scali, AW Beck e mais 3. Percutaneous thoracic endovascular aortic repair is not contraindicated in obese patients. J Vasc Surg, 2014quem mais cita →
- 15RJ Applegate. Vascular closure device failure we are getting better but not there yet. JACC Cardiovasc Interv, 2012quem mais cita →
- 16WA Lee, MP Brown, PR Nelson e mais 1. Total percutaneous access for endovascular aortic aneurysm repair ("Preclose" technique). J Vasc Surg, 2007quem mais cita →
- 17WH Kim, S Shin, YG Ko e mais 3. Efficacy and safety of the preclose technique following percutaneous aortic stent-graft implantation. J Endovasc Ther, 2013quem mais cita →
- 18JM Manunga, P Gloviczki, GS Oderich e mais 3. Femoral artery calcification as a determinant of success for percutaneous access for endovascular abdominal aortic aneurysm repair. J Vasc Surg, 2013quem mais cita →
- 19T Ichihashi, T Ito, Y Kinoshita e mais 2. Safety and utility of total percutaneous endovascular aortic repair with a single Perclose ProGlide closure device. J Vasc Surg, 2016quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
3 pessoas- João Antônio Correa1 artigo · 2025
- Daniel Santos Costa1 artigo · 2025
- Sidnei José Galego1 artigo · 2025
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda