Brazilian Journal of Cardiovascular Surgery2015

Efficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available?

Giovani José Dal Poggetto Molinari, Ana Terezinha Guillaumon e Andréia Marques de Oliveira Dalbem

em inglês

citado por 2 artigoscita 23 obras

resumo

ABSTRACT INTRODUCTION: Despite the patient and medical staff exposure to radiation in endovascular aneurysm repair, the benefits of this abdominal aortic aneurysm type of surgical management are justfied by minor recovery time and hospitalization, as well as an option for patients not elected to conventional open repair. In this minimally invasive surgical aproach, time of procedure and radiation doses can be substantial - and the increasing frequency of these procedures and it's complexity have impelled vascular surgeons to face additional and successive risk to occupational radiation exposure. Meticulous study of the computed tomography angiography during the endovascular aneurysm repair preparation allows reduction of unnecessary radiation exposure, as also reduces consecutive image acquisition and contrast use (that may be related to renal overload in susceptible patients). Some studies have proposed strategies to optimize endovascular intervention to reduce contrast use and X-ray exposure. Although they might prove to be effective, they rely on use of additional specific and advanced equipment, available only in major centers. As an alternative to this expensive and restrict technology, it is presented a simpler technique through image manipulation on software OsiriX, aiming to reduce both exposures. OBJECTIVE: To analyze the efficacy of the adoption of a study protocol and a script-based guide in preparation for endovascular aneurysm repair through verifying it's impact over the surgical procedure - as referred to intravascular contrast infuse, effects over renal function, blood loss and operatory time. METHODS: A longitudinal prospective study from March 2014 through March 2015, where 30 performed endovascular aneurysm repair were compared to a historic control group. The planning for endovascular aneurysm repair through the patient's tomographic image manipulation in the prospective group was performed with OsiriX MD software. A script-based guide upon gathering detailed computed tomography angiography images was elaborated by the author and distributed to the performing surgical team for appreciation, instruction and pre operatory judgment. Based upon the script, the C-arm gantry angle was specifically corrected in each case of endovascular aneurysm repair, for image optimization and aneurysm's neck visualization. Arteriography was performed under digital subtraction angiography after catheters were positioned according to predicted level description in the referred guide. Statistical analysis were performed with a significance level of 5% (P value<0.05). RESULTS: There was a statistically significant relationship between the two studied periods and the variables: contrast volume (284.5 vs. 31.8 mL), operative time (207.5 vs. 140.4 min.) and blood loss (798.1 vs. 204.4 mL), revealing that they are considerably larger in the historical control group than in the script guided current group. There was no difference related to the volume of

como citar · ABNT NBR 6023

MOLINARI, Giovani José Dal Poggetto; GUILLAUMON, Ana Terezinha; DALBEM, Andréia Marques de Oliveira. Efficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available? Brazilian Journal of Cardiovascular Surgery, 2015. DOI: 10.5935/1678-9741.20150079.

Referências

23 obras citadas

  1. 1H Rousseau, V Chabbert, MA Maracher e mais 3. The importance of imaging assessment before endovascular repair of thoracic aorta. Eur J Vasc Endovasc Surg, 2009quem mais cita →
  2. 2MC Walls, P Thavendiranathan e S Rajagopalan. Advances in CT angiography for peripheral arterial disease. Cardiol Clin, 2011quem mais cita →
  3. 3TG Walker, SP Kalva, S Ganguli e mais 3. Image optimization during endovascular aneurysm repair. AJR Am J Roentgenol, 2012quem mais cita →
  4. 4BW Ullery, B Landau, GJ Wang e mais 2. Radiation dose to the interventionalist is directly affected by the operating position. Vascular, 2014quem mais cita →
  5. 5B Maurel, A Hertault, J Sobocinski e mais 3. Techniques to reduce radiation and contrast volume during EVAR. J Cardiovasc Surg, 2014quem mais cita →
  6. 6PCA Ribeiro e MJS Ribeiro. Meios de constraste. Cirurgia endovascular, 2010
  7. 7F Stacul, AJ van der Molen, P Reimer e mais 3. Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines. Eur Radiol, 2011quem mais cita →
  8. 8M Canyigit, L Cetin, E Uguz e mais 3. Reduction of iodinated contrast load with the renal artery catheterization technique during endovascular aortic repair. Diagn Interv Radiol, 2013quem mais cita →
  9. 9MM McNally, ST Scali, RJ Feezor e mais 3. Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair. J Vasc Surg, 2015quem mais cita →
  10. 10GJ Molinari, AM Dalbem, FH Menezes e mais 1. Proposal of renal artery's ostial projection under virtual geometric correction in infrarenal aneurysms: initial results of a pilot study. Rev Bras Cir Cardiovasc, 2014quem mais cita →
  11. 11GJ Molinari, AM Dalbem e AT Guillaumon. The use of virtual resources in preoperative preparation of infrarenal aneurysms: exploring the OsiriX's potential. Rev Bras Cir Cardiovasc, 2014quem mais cita →
  12. 12GS Oderich e RD Malgor. Aneurisma da aorta toracoabdominal. Cirurgia endovascular, 2010quem mais cita →
  13. 13IR Kuroki, FV Magalhães, P Rizzi e mais 1. Angiotomografia. Cirurgia vascular: cirurgia endovascular, angiologia, 2013
  14. 14RW Geenen, HJ Kingma e AJ van der Molen. Contrast-induced nephropathy: pharmacology, pathophysiology and prevention. Insights Imaging, 2013quem mais cita →
  15. 15U Nyman, J Björk, P Aspelin e mais 1. Contrast medium dose-to-GFR ratio: a measure of systemic exposure to predict contrast-induced nephropathy after percutaneous coronary intervention. Acta Radiol, 2008quem mais cita →
  16. 16JM Alsac, CK Zarins, MA Heikkinen e mais 3. The impact of aortic endografts on renal function. J Vasc Surg, 2005quem mais cita →
  17. 17SA Badger, C Jones, CS Boyd e mais 1. Determinants of radiation exposure during EVAR. Eur J Vasc Endovasc Surg, 2010quem mais cita →
  18. 18FA Lederle, JA Freischlag, TC Kyriakides e mais 3. Outcomes following endovascular vs open repair of abdominal aortic aneurysm: a randomized trial. JAMA, 2009quem mais cita →
  19. 19M Prinssen, EL Verhoeven, J Buth e mais 3. A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. N Engl J Med, 2004quem mais cita →
  20. 20JP Carpenter, RM Fairman, CF Barker e mais 3. Endovascular AAA repair in patients with renal insufficiency: strategies for reducing adverse renal events. Cardiovasc Surg, 2001quem mais cita →
1–20 de 23 obras citadas

Quem cita esta obra

2 artigos do acervo

ano a anomais citada em 2016 · 2 artigos
Mais citada em 2016, com 2 artigos.
  • 2016: citada em 2 artigos

quem fala desta obra

8 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações