Revista Brasileira de Ortopedia2024

Comparative Functional and Isokinetic Analysis between Implants with Posterior Stabilization and Rotating Hinge Total Knee Arthroplasty

Sandra Tie Nishibe Minamoto, Alan de Paula Mozella, Victor Rodrigues Amaral Cossich, Ubiratã Faleiro Gavilão, Heitor Schuabb Machado e João Maurício Barretto

em inglês

cita 30 obras, 2 no acervo

resumo

Abstract Objective: To compare the function and muscle strength of the limb between patients undergoing knee arthroplasties using primary implants with posterior stabilization (control group) and patients with rotating hinge implants (Hinge group). Methods: Function assessment was performed using the Knee Society Score (KSS) and muscle strength using an isokinetic dynamometer using a speed of 60°/s. Results: 43 patients were analyzed, who underwent 51 surgeries, with the Hinge group comprising 25 surgeries and the control group comprising 26 primary surgeries. We did not observe significant differences between the Hinge and control groups in the values of functional KSS (p = 0.54), objective KSS (p = 0.91), peak flexor torque (p = 0.25) and peak extensor torque (p = 0.08). Patients in the Hinge group who underwent primary arthroplasties had a higher peak flexor torque (0.76 Nm/kg) than those who used the implant in revision after septic failure (0.33 Nm/kg) (p <0.05). The constrained implant was indicated in arthroplasty revision surgeries with severe ligament instability and in cases of complex primary arthroplasties with bone destruction or severe coronal deformity in the coronal plane. Conclusion: The use of constrained implants enables joint function and muscle strength comparable to patients who underwent primary arthroplasty using conventional implants with posterior stabilization. Patients undergoing septic revision with a rotating Hinge prosthesis exhibit lower flexor muscle strength compared to those undergoing primary arthroplasty with a constrained implant.

como citar · ABNT NBR 6023

MINAMOTO, Sandra Tie Nishibe et al. Comparative Functional and Isokinetic Analysis between Implants with Posterior Stabilization and Rotating Hinge Total Knee Arthroplasty. Revista Brasileira de Ortopedia, 2024. DOI: 10.1055/S-0044-1779685.

Referências

30 obras citadas · 2 no acervo

  1. 1SKS Marya e C. Singh. Options and limitations of implant constraint. J Orthop, 2020quem mais cita →
  2. 2T Gehrke, D Kendoff e C. Haasper. The role of hinges in primary total knee replacement. Bone Joint J, 2014quem mais cita →
  3. 3JS Bingham, BR Bukowski, CC Wyles e mais 3. Rotating-Hinge Revision Total Knee Arthroplasty for Treatment of Severe Arthrofibrosis. J Arthroplasty, 2019quem mais cita →
  4. 4B. Walldius. Arthroplasty of the knee joint employing an acrylic prosthesis. Acta Orthop Scand, 1953quem mais cita →
  5. 5P Ruggieri, AF Mavrogenis, E Pala e mais 2. Long term results of fixed-hinge megaprostheses in limb salvage for malignancy. Knee, 2012quem mais cita →
  6. 6JA Rand, EY Chao e RN. Stauffer. Kinematic rotating-hinge total knee arthroplasty. J Bone Joint Surg Am, 1987quem mais cita →
  7. 7RL. Barrack. Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res, 2001quem mais cita →
  8. 8D Kendoff, C Haasper, T Gehrke e mais 2. Management of Gonarthrosis with a Rotating Hinge Prosthesis: Minimum 10-Year Follow-up. Clin Orthop Surg, 2020quem mais cita →
  9. 9JR Yoon, JY Cheong, JT Im e mais 3. Correction: Rotating hinge knee versus constrained condylar knee in revision total knee arthroplasty: A meta-analysis. PLoS One, 2019quem mais cita →
  10. 10W Barnoud, A Schmidt e J Swan. Condylar constrained knee prosthesis and rotating hinge prosthesis for revision total knee arthroplasty for mechanical failure have not the same indications and same results. SICOT J, 2021quem mais cita →
  11. 11ALP Silva, MK Demange, RG Gobbi e mais 3. Translation and Validation of the Knee Society Score - KSS for Brazilian Portuguese. Acta Ortop Bras, 2012quem mais cita →
  12. 12CP Helito, PN Giglio, CM Cavalheiro e mais 3. Knee arthroplasty with rotating-hinge implant: an option for complex primary cases and revisions. Rev Bras Ortop, 2018no acervo →
  13. 13FJ Angelini, CP Helito, BA Veronesi e mais 3. Knee arthroplasty revision with a constrained implant using hinge and rotating tibial basis. Acta Ortop Bras, 2016no acervo →
  14. 14SP Boelch, J Arnholdt, BM Holzapfel e mais 3. Revision knee arthroplasty with rotating hinge systems in patients with gross ligament instability. Int Orthop, 2018quem mais cita →
  15. 15J Arnholdt, SP Boelch, F Dogan e mais 3. Revision arthroplasty with rotating hinge systems for total knee arthroplasty instability. Oper Orthop Traumatol, 2020quem mais cita →
  16. 16L Felli, M Coviello, M Alessio-Mazzola e mais 1. The Endo-Model (®) rotating hinge for rheumatoid knees : Functional results in primary and revision surgery. Orthopade, 2016quem mais cita →
  17. 17G Petrou, H Petrou e C Tilkeridis. Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up. J Bone Joint Surg Br, 2004quem mais cita →
  18. 18F Sanguineti, T Mangano, M Formica e mais 1. Total knee arthroplasty with rotating-hinge Endo-Model prosthesis: clinical results in complex primary and revision surgery. Arch Orthop Trauma Surg, 2014quem mais cita →
  19. 19C Böhler, P Kolbitsch, R Schuh e mais 3. Midterm results of a new rotating hinge knee implant: a 5-year follow-up. BioMed Res Int, 2017quem mais cita →
  20. 20DM Spranz, KA Koch, T Reiner e mais 3. Mid-term results of complex primary total knee arthroplasty using a rotating-hinge implant. Knee, 2022quem mais cita →
1–20 de 30 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações