Revista Brasileira de Ortopedia2021

Measuring Acetabular Version after Total Hip Arthroplasty: A Comparison of Two Radiographic Methods

Afonso Cardoso, Mafalda Duarte, Rui Viegas, Filipe Oliveira, Pedro Pinto e Paulo Rego

em inglês

cita 21 obras

resumo

Abstract Objective The objective of the present work was to compare the measurement of acetabular component version on anteroposterior (AP) and on cross-table radiographs after total hip arthroplasty (THA). Methods Radiographs of 60 hips with a primary THA were selected. Version was calculated on the AP radiograph using the Lewinnek method and, on the cross-table, using the Woo and Morrey direct method. Results Mean and standard deviation (SD) were different on both radiographs, being 9.7° ± 5.5° on the AP, whereas in the cross-table the measurements were 20.6° ± 8.4° (p < 0.001). Minding our aim of 10°, the cross-table measurements were statistically different from it (p < 0.001), while the AP measurement did not differ (p = 0.716). Conclusion The present study showed that the best way to correctly evaluate the acetabular component positioning following a THA is by measuring anteversion and abduction on an AP radiograph after confirming, in a cross-table radiograph, that the component is not retroverted.

como citar · ABNT NBR 6023

CARDOSO, Afonso et al. Measuring Acetabular Version after Total Hip Arthroplasty: A Comparison of Two Radiographic Methods. Revista Brasileira de Ortopedia, 2021. DOI: 10.1055/S-0040-1721360.

Referências

21 obras citadas

  1. 1J. Charnley. Total hip replacement by low-friction arthroplasty.. Clin Orthop Relat Res, 1970quem mais cita →
  2. 2H Del Schutte Jr, AJ Lipman, SM Bannar e mais 3. Effects of acetabular abduction on cup wear rates in total hip arthroplasty.. J Arthroplasty, 1998quem mais cita →
  3. 3KH Widmer e B. Zurfluh. Compliant positioning of total hip components for optimal range of motion.. J Orthop Res, 2004quem mais cita →
  4. 4RY Woo e BF. Morrey. Dislocations after total hip arthroplasty.. J Bone Joint Surg Am, 1982quem mais cita →
  5. 5DW. Murray. The definition and measurement of acetabular orientation.. J Bone Joint Surg Br, 1993quem mais cita →
  6. 6R Biedermann, A Tonin, M Krismer e mais 3. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component.. J Bone Joint Surg Br, 2005quem mais cita →
  7. 7GE Lewinnek, JL Lewis, R Tarr e mais 2. Dislocations after total hip-replacement arthroplasties.. J Bone Joint Surg Am, 1978quem mais cita →
  8. 8MK Ackland, WB Bourne e HK. Uhthoff. Anteversion of the acetabular cup.. Measurement of angle after total hip replacement. J Bone Joint Surg Br, 1986quem mais cita →
  9. 9O Müller, P Reize, D Trappmann e mais 1. Measuring anatomical acetabular cup orientation with a new X-ray technique.. Comput Aided Surg, 2006quem mais cita →
  10. 10JH Nho, YK Lee, HJ Kim e mais 3. Reliability and validity of measuring version of the acetabular component.. J Bone Joint Surg Br, 2012quem mais cita →
  11. 11JD Visser e JG. Konings. A new method for measuring angles after total hip arthroplasty.. A study of the acetabular cup and femoral component. J Bone Joint Surg Br, 1981quem mais cita →
  12. 12KH. Widmer. A simplified method to determine acetabular cup anteversion from plain radiographs.. J Arthroplasty, 2004quem mais cita →
  13. 13N Arai, S Nakamura e T. Matsushita. Difference between 2 measurement methods of version angles of the acetabular component.. J Arthroplasty, 2007quem mais cita →
  14. 14MB. Coventry. Late dislocations in patients with Charnley total hip arthroplasty.. J Bone Joint Surg Am, 1985quem mais cita →
  15. 15M Seki, N Yuasa e K. Ohkuni. Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation.. J Orthop Res, 1998quem mais cita →
  16. 16MP Abdel, P von Roth, MT Jennings e mais 2. What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.. Clin Orthop Relat Res, 2016quem mais cita →
  17. 17CI Esposito, BP Gladnick e YY Lee. Cup position alone does not predict risk of dislocation after hip arthroplasty.. J Arthroplasty, 2015quem mais cita →
  18. 18BM Jolles, P Zangger e PF. Leyvraz. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.. J Arthroplasty, 2002quem mais cita →
  19. 19YC Ha, JJ Yoo, YK Lee e mais 2. Acetabular component positioning using anatomic landmarks of the acetabulum.. Clin Orthop Relat Res, 2012quem mais cita →
  20. 20D Bhaskar, A Rajpura e T Board. Current Concepts in Acetabular Positioning in Total Hip Arthroplasty. Indian J Orthop, 2017quem mais cita →
1–20 de 21 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações