ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR) with different closed suction drains (3.2-mm and 4.8-mm gauge). METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery). The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005); in the first 24 h, there was major bleeding in Group II (mean 893 mL), with a significant difference (p = 0.004). Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710). The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394). CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.
como citar · ABNT NBR 6023
LEAO, Marcos George de Souza et al. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges. Revista Brasileira de Ortopedia, 2016. DOI: 10.1016/J.RBOE.2016.08.014.
Referências
27 obras citadas · 1 no acervo
- 1M Levy. Intraperitoneal drainage. Am J Surg, 1984quem mais cita →
- 2ES Seo, SW Yoon, IJ Koh e mais 2. Subcutaneous versus intraarticular indwelling closed suction drainage after TKA a randomized controlled trial. Clin Orthop Relat Res, 2010quem mais cita →
- 3KJ Beer, AV Lombardi Jr, TH Mallory e mais 1. The efficacy of suction drains after routine total joint arthroplasty. J Bone Joint Surg Am, 1991quem mais cita →
- 4S Al-Zahid e AP Davies. Closed suction drains, reinfusion drains or no drains in primary total knee replacement. Ann R Coll Surg Engl, 2012quem mais cita →
- 5R Keska, TP Paradowski e D Witonski´. Outcome in primary cemented total knee arthroplasty with or without drain A prospective comparative study. Indian J Orthop, 2014quem mais cita →
- 6E Gibon, JP Courpied e M Hamadouche. Total joint replacement and blood loss what is the best equation?. Int Orthop, 2013quem mais cita →
- 7S Kumar, S Penematsa e S Parekh. Are drains required following a routine primary total joint arthroplasty. Int Orthop, 2007quem mais cita →
- 8GL Camanho, R Olivi e LF Camanho. Artroplastia total de joelho em pacientes idosos portadores de osteoartrose. Rev Bras Ortop, 1998quem mais cita →
- 9S Ahlbäck. Osteoarthrosis of the knee A radiographic investigation. Acta Radiol Diagn (Stockh), 1968quem mais cita →
- 10GW Keyes, AJ Carr, RK Miller e mais 1. The radiographic classification of medial gonarthrosis Correlation with operation methods in 200 knees. Acta Orthop Scand, 1992quem mais cita →
- 11Colunista Portal Edução. Dreno. 2015
- 12SB Nadler, JH Hidalgo e T Bloch. Prediction of blood volume in normal human adults. Surgery, 1962quem mais cita →
- 13F Mercuriali e G Inghilleri. Proposal of an algorithm to help the choice of the best transfusion strategy. Curr Med Res Opin, 1996quem mais cita →
- 14S Vieira. Bioestatística - Tópicos avançados. 2004quem mais cita →
- 15EPI-INFO. Versão 7.4 para windows, produzido e distribuído gratuitamente pelo Centro de Controle de Doenças - CDC. 2015quem mais cita →
- 16CN Esler, C Blakeway e NJ Fiddian. The use of a closed-suction drain in total knee arthroplasty A prospective, randomised study. J Bone Joint Surg Br, 2003quem mais cita →
- 17MJ Parker, CP Roberts e D Hay. Closed suction drainage for hip and knee arthroplasty A meta- analysis. J Bone Joint Surg Am, 2004quem mais cita →
- 18RFA Goes, AF Silva, FS Lyra e mais 3. Estudo prospectivo randomizado após uso de dreno na artroplastia total do joelho com implante. Rev Bras Ortop, 2013quem mais cita →
- 19N Roy, M Smith, M Anwar e mais 1. Delayed release of drain in total knee replacement reduces blood loss A prospective randomised study. Acta Orthop Belg, 2006quem mais cita →
- 20D Willemen, J Paul, SH White e mais 1. Close suction drainage following knee arthroplasty Effectiveness and risks. Clin Orthop Relat Res, 1991quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda