Revista Brasileira de Ortopedia2015

Preliminary analysis on the MD-4(r) plasma-sprayed titanium acetabular component

Elmano de Araújo Loures, Leandro Furtado Simoni, Isabel Cristina Gonçalves Leite, Daniel Naya Loures e Clarice Naya Loures

em inglês

cita 32 obras, 2 no acervo

resumo

OBJECTIVES: To evaluate the short-term performance of a type of implant manufactured in Brazil.METHODS: This study analyzed a cohort of 60 patients who underwent implantation of MD-4(r) acetabular components during primary hip arthroplasty procedures performed between January 1, 2010, and August 1, 2012. The patients were studied retrospectively with regard to clinical behavior, stability and radiological osseointegration. The patients were followed up for a minimum of 12 months and a maximum of 42 months (mean: 27) and were evaluated by means of the Harris Hip Score, SF-36 questionnaire and serial conventional radiographs.RESULTS: All the components were radiologically stable, without evidence of migration or progressive radiolucency lines. On average, the Harris Hip Score evolved from 36.1 to 92.1 (p < 0.001) and the SF-36 showed significant increases in all its domains (p < 0.001). No differences were observed among patients with osteoarthrosis, osteonecrosis, hip dysplasia or other conditions.CONCLUSIONS: The short-term results showed clinical and radiological signs of stability and osseointegration of the implants, which may represent a predictive factor regarding medium-term survival of this acetabular component.

como citar · ABNT NBR 6023

LOURES, Elmano de Araújo et al. Preliminary analysis on the MD-4(r) plasma-sprayed titanium acetabular component. Revista Brasileira de Ortopedia, 2015. DOI: 10.1016/J.RBOE.2015.03.003.

Referências

32 obras citadas · 2 no acervo

  1. 1F D'Angelo, L Murena, M Campagnolo e mais 2. Analysis of bone ingrowth on a tantalum cup. Indian I Orthop, 2008quem mais cita →
  2. 2H Stallforth e W Blömer. Biomechanical and technological aspects of cementless hip implants. The bicontacthip implant system, 1994quem mais cita →
  3. 3S Weller e R Volkmann. The bicontacthip implant system. 1994quem mais cita →
  4. 4CA Engh, ID Bobyn e AH Glassman. Porous coated hip replacement: factors governing bone ingrowth, stress shielding and clinical results. I Bone Ioint Surg Br, 1987quem mais cita →
  5. 5SM Rohrl, B Nivbrant, F Snorrason e mais 2. Porous-coated cups fixed with screws: a 12 year clinical and radiostereometric follow-up study of 50 hips. Acta Orthop, 2006quem mais cita →
  6. 6KN Malizos, K Bargiotas, L Papatheodorou e mais 2. Survivorship of monoblock trabecular metal cups in primary THA: midterm results. Clin Orthop Relat Res, 2008quem mais cita →
  7. 7RL Barrack, RD Ir Mulroy e WH Harris. Improved cementing techniques and femoral component loosening in young patients with arthroplasty: a 12 year radiographic review. I Bone Ioint Surg Br, 1992quem mais cita →
  8. 8ASTM International. ASTM F136-08e1 standard specification for wrought titanium-6 aluminum-4 vanadium ELI (extra low interstitial) alloy for surgical implant applications (UNS R56401). 2008quem mais cita →
  9. 9IH Kellgren e IS Lawrence. Radiological assessment of osteoarthrosis. Ann Rheum Dis, 1957quem mais cita →
  10. 10RP Guimarães, DPL Alves, GB Silva e mais 3. Traduc¸ão e adaptac¸ão transcultural do instrumento de avaliac¸ão do quadril Harris Hip Score. Acta Ortop Bras, 2010no acervo →
  11. 11IM Quintana, A Escobar, U Aguirre e mais 2. Predictors of health-related quality-of-life change after total hip arthroplasty. Clin Orthop Relat Res, 2009quem mais cita →
  12. 12K Hardinge. The direct lateral approach to the hip. I Bone Ioint Surg Br, 1982quem mais cita →
  13. 13EA Salvati, NE Sharrock, G Westrich e mais 3. The 2007 ABIS Nicolas Andry Award: three decades of clinical, basic, and applied research on thromboembolic disease after THA: rationale and clinical results of a multimodal prophylaxis protocol. Clin Orthop Relat Res, 2007quem mais cita →
  14. 14GE Lewinnek, IL Lewis, R Tarr e mais 2. Dislocations after total hip replacement arthroplasties. I Bone Ioint Surg Am, 1978quem mais cita →
  15. 15D Nunn, MA Freeman, PF Hill e mais 1. The measurement of migration of the acetabular component of hip prostheses. I Bone Ioint Surg Br, 1989quem mais cita →
  16. 16S Lakemeier, G Aurand, N Timmesfeld e mais 3. Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years. BMC Musculoskelet Disord, 2010quem mais cita →
  17. 17HA Latimer e PF Lachiewicz. Porous-coated acetabular components with screw fixation. Five to ten-year results. I Bone Ioint Surg Am, 1996quem mais cita →
  18. 18BT Rabello, FP Cabral, E Freitas e mais 3. Artroplastia total do quadril não cimentada em pacientes com artrite reumatoide. Rev Bras Ortop, 2008no acervo →
  19. 19RE Ir White. Evaluation of the painful total hip replacement. The adult hip, 2007quem mais cita →
  20. 20IG DeLee e I Charnley. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res, 1976quem mais cita →
1–20 de 32 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações