Revista Brasileira de Ortopedia2014
Total knee arthroplasty with computer-assisted navigation: an analysis of 200 cases,
Marcus Vinicius Malheiros Luzo, Luiz Felipe Morlin Ambra, Pedro Debieux, Carlos Eduardo da Silveira Franciozi, Raquel Ribeiro Costi, Marcelo de Toledo Petrilli, Marcelo Seiji Kubota, Leonardo José Bernardes Albertoni, Antônio Altenor Bessa de Queiroz, Fábio Pacheco Ferreira, Geraldo Sérgio de Mello Granata Júnior e Mário Carneiro Filho
em inglês
resumo
OBJECTIVE: to evaluate the results from surgery with computer-assisted navigation in cases of total knee arthroplasty.METHOD: a total of 196 patients who underwent total knee arthroplasty with computer-assisted navigation were evaluated. The extension and flexion spaces (gaps) were evaluated during the operation and the alignment after the operation was assessed. The Knee Society Score (KSS) questionnaire for assessing patient's function was applied preoperatively and postoperatively after a mean follow-up of 22 months.RESULTS: in all, 86.7% of the patients presented good alignment of the mechanical axis (less than 3◦ of varus or valgus in relation to the mechanical axis) and 96.4% of the patients presented balanced flexion and extension gaps. Before the operation, 97% of the patients presented poor or insufficient KSS, but after the operation, 77.6% presented good or excellent KSS.CONCLUSION: the navigation system made it possible to achieve aligned and balanced implants, with notable functional improvement among the patients. It was found to be useful in assessing, understanding and improving knowledge in relation to performing arthroplasty procedures.
como citar · ABNT NBR 6023
LUZO, Marcus Vinicius Malheiros et al. Total knee arthroplasty with computer-assisted navigation: an analysis of 200 cases,. Revista Brasileira de Ortopedia, 2014. DOI: 10.1016/J.RBOE.2014.03.001.
Referências
21 obras citadas
- 1RS Jeffery, RW Morris e RA Denham. Coronal alignment after total knee replacement. J Bone Joint Surg Br, 1991quem mais cita →
- 2KY Chiu, WP Yau, TP Ng e mais 1. The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty. Int Orthop (SICO), 2007quem mais cita →
- 3MA Yaffe, SS Koo e SD Stulberg. Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res, 2008quem mais cita →
- 4N Friederich e R Verdonk. The use of computer- assisted orthopedic surgery for total knee replacement in daily practice: a survey among ESSKA/SGO-SSO members. Knee Surg Sports Traumatol Arthrosc, 2008quem mais cita →
- 5JN Insall, CS Ranawat, P Aglietti e mais 1. A comparison of four models of total knee- replacement prostheses. J Bone Joint Surg Am, 1976quem mais cita →
- 6BG Drake, CM Callahan, RS Dittus e mais 1. Global rating systems used in assessing knee arthroplasty outcomes. J Arthroplasty, 1994quem mais cita →
- 7AP Davies. Rating systems for total knee replacement. Knee, 2002quem mais cita →
- 8DG Lewallen, RS Bryan e LF Peterson. Polycentric total knee arthroplasty. A ten- year follow-up study. J Bone Joint Surg Am, 1984quem mais cita →
- 9BM Hetaimish, MM Khan, N Simunovic e mais 3. Meta- analysis of navigation vs conventional total knee arthroplasty. J Arthroplasty, 2012quem mais cita →
- 10K Ishida, T Matsumoto, N Tsumura e mais 3. Mid-term outcomes of computer- assisted total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc, 2011quem mais cita →
- 11LM Longstaff, K Sloan, N Stamp e mais 2. Good alignment aftertotal knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty, 2009quem mais cita →
- 12L Molfetta e D Caldo. Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow- up. Knee, 2008quem mais cita →
- 13JM Spencer, SK Chauhan, K Sloan e mais 2. Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br, 2007quem mais cita →
- 14H Bäthis, L Perlick, M Tingart e mais 3. Alignment in total knee arthroplasty. A comparison of computer- assisted surgery with the conventional technique. J Bone Joint Surg Br, 2004quem mais cita →
- 15A Martin, O Wohlgenannt, M Prenn e mais 2. Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res, 2007quem mais cita →
- 16M Tingart, C Lüring, H Bäthis e mais 3. Computer- assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine?. Knee Surg Sports Traumatol Arthrosc, 2007quem mais cita →
- 17LM Jennings, CI Bell, E Ingham e mais 3. The influence of femoral condylar liftoff on the wear of artificial knee joints. Proc Inst Mech Eng H, 2007quem mais cita →
- 18TK Fehring. Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res, 2000quem mais cita →
- 19DA Dennis, RD Komistek, RH Kim e mais 1. Gap balancing versus measured resection technique for total knee arthroplasty. Clin Orthop Relat Res, 2009quem mais cita →
- 20N Pang H-, SJ Yeo, H-C Chong e mais 3. Computer- assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc, 2011quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda