A CHEMICAL REACTION OPTIMIZATION ALGORITHM FOR PHASOR MEASUREMENT UNIT PLACEMENT
Aileen Carniel e Mario Mestria
em inglês
resumo
ABSTRACT Optimal Phasor Measurement Unit (PMU) Placement (OPP) aims to reduce equipment costs while maintaining electrical systems observability. PMUs synchronized phasor data provide electrical systems information with high quality and frequency enabling the implementation of faster than real-time state estimators. We applied Chemical Reaction Optimization (CRO) method at OPP problem, testing it successfully at IEEE power system databases (14, 30, 57 and 118 bars) through two distinct models. The relationships between CRO parameters and the occurrence of elementary reactions was exploited, achieving better results through specific reactions. Due to problems similarity and larger scales, the software was adapted to Beasley OR-Library Set Covering (SC) problems. In the process to achieve GAPs smaller than 10% for some files, we tried out dedicated local searches, disturbance recurrence limits and stop condition changes. However, we suggest continuing to evaluate CRO method adherence to SC problem using different data structures to decrease computational times.
como citar · ABNT NBR 6023
CARNIEL, Aileen; MESTRIA, Mario. A CHEMICAL REACTION OPTIMIZATION ALGORITHM FOR PHASOR MEASUREMENT UNIT PLACEMENT. Pesquisa Operacional, 2021. DOI: 10.1590/0101-7438.2021.041.00231454.
Referências
30 obras citadas · 2 no acervo
- 1A AHMADI, Y ALINEJAD-BEROMI e M MORADI. Optimal PMU placement for power system observability using binary particle swarm optimization and considering measurement redundancy. Expert Systems with Applications, 2011quem mais cita →
- 2TL BALDWIN, L MILI, MB BOISEN e mais 1. Power System Observability with Minimal Phasor Measurement Placement. IEEE Transactions on Power Systems, 1993quem mais cita →
- 3JE. BEASLEY. OR-Library for Set Covering test data sets. 1990quem mais cita →
- 4PP BEDEKAR, SR BHIDE e VS KALE. Optimum PMU placement considering one Line/ One PMU outage and maximum redundancy using genetic algorithm. The 8th Electrical Engineering/ Electronics, Computer, Telecommunications and Information Technology (ECTI) Association of Thailand - Conference 2011, 2011quem mais cita →
- 5EM CAVALHEIRO, AH VERGÍLIO e C LYRA. Optimal configuration of power distribution networks with variable renewable energy resources. Computers & Operations Research, 2018quem mais cita →
- 6DJ BRUENI e LS HEATH. The PMU Placement Problem. SIAM Journal on Discrete Mathematics, 2005quem mais cita →
- 7M HAJIAN, AM RANJBAR, T AMRAEE e mais 1. Optimal placement of PMUs to maintain network observability using a modified BPSO algorithm. International Journal of Electrical Power and Energy Systems, 2011quem mais cita →
- 8J HUANG e NE WU. Fault-tolerant placement of phasor measurement units based on control reconfigurability. Control Engineering Practice, 2013quem mais cita →
- 9Z HUI-LING, D YUAN-XIU, Z XIAO-PAN e mais 2. Hybrid of MST and Genetic Algorithm on Minimizing PMU Placement. 2013 Third International Conference on Intelligent System Design and Engineering Applications, 2013quem mais cita →
- 10IEEE. Power Systems Test Casesquem mais cita →
- 11K JAMUNA e KS SWARUP. Power system observability using biogeography based optimization. 2011quem mais cita →
- 12K JAMUNA e KS SWARUP. Multi-objective biogeography based optimization for optimal PMU placement. Applied Soft Computing, 2012quem mais cita →
- 13NC KOUTSOUKIS, NM MANOUSAKIS, PS GEORGILAKIS e mais 1. Numerical observability method for optimal phasor measurement units placement using recursive tabu search method. IET Generation, Transmission and Distribution, 2013quem mais cita →
- 14AYS LAM e VOK LI. Chemical-reaction-inspired metaheuristic for optimization. IEEE Transactions on Evolutionary Computation, 2010quem mais cita →
- 15AYS LAM e VOK LI. Chemical Reaction Optimization: A tutorial. Memetic Computing, 2012quem mais cita →
- 16C-S. LIAO, T-J. HSIEH, X-C. GUO e mais 2. Hybrid search for the optimal PMU placement problem on a power grid. European Journal of Operational Research, 2015quem mais cita →
- 17B MOHAMMADI-IVATLOO. Optimal Placement of PMUs for Power System Observability Using Topology Based Formulated Algorithms. J Appl Sci, 2009quem mais cita →
- 18MB MOHAMMADI, RA HOOSHMAND e FH FESHARAKI. A new approach for optimal placement of PMUs and their required communication infrastructure in order to minimize the cost of the WAMS. IEEE Transactions on Smart Grid, 2016quem mais cita →
- 19M NAZARI-HERIS e B. MOHAMMADI-IVATLOO. Application of heuristic algorithms to optimal PMU placement in electric power systems: An updated review. Renewable and Sustainable Energy Reviews, 2015quem mais cita →
- 20NIST. NIST PAP2 guidelines for assessing wireless standards for smart grid application. 2012quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda