Pesquisa Veterinária Brasileira2013

Comparison of two methods of tear sampling for protein quantification by Bradford method

Eliana Farias, Katia L. Yasunaga, Romulo V.R. Peixoto, Micaella P. Fonseca, Wagner Fontes e Paula D. Galera

em inglês

citado por 1 artigocita 25 obras

resumo

The aim of this study was to compare two methods of tear sampling for protein quantification. Tear samples were collected from 29 healthy dogs (58 eyes) using Schirmer tear test (STT) strip and microcapillary tubes. The samples were frozen at -80ºC and analyzed by the Bradford method. Results were analyzed by Student's t test. The average protein concentration and standard deviation from tears collected with microcapillary tube were 4.45mg/mL ±0.35 and 4,52mg/mL ±0.29 for right and left eyes respectively. The average protein concentration and standard deviation from tears collected with Schirmer Tear Test (STT) strip were and 54.5mg/mL ±0.63 and 54.15mg/mL ±0.65 to right and left eyes respectively. Statistically significant differences (p<0.001) were found between the methods. In the conditions in which this study was conducted, the average protein concentration obtained with the Bradford test from tear samples obtained by Schirmer Tear Test (STT) strip showed values higher than those obtained with microcapillary tube. It is important that concentration of tear protein pattern values should be analyzed according the method used to collect tear samples.

como citar · ABNT NBR 6023

FARIAS, Eliana et al. Comparison of two methods of tear sampling for protein quantification by Bradford method. Pesquisa Veterinária Brasileira, 2013. DOI: 10.1590/S0100-736X2013000200021.

Referências

25 obras citadas

  1. 1S. Ananthi, T. Chitra, R. Bini e mais 3. Comparative analysis of the tear protein profile in mycotic keratitis patients. Molecular Vision, 2008quem mais cita →
  2. 2R. Barrera, A. Jiménez, R. López e mais 3. Evaluation of total protein content in tears of dogs by polyacrylamide gel disk electrophoresis. Am. J. Vet. Res., 1992quem mais cita →
  3. 3S. Barabino, W. Chena e M.R. Dana. Tear film and ocular surface tests in animal models of dry eye: uses and limitations. Exp. Eye Res., 2004quem mais cita →
  4. 4M.M. Bradford. Rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. Analyt. Biochem., 1976quem mais cita →
  5. 5C.F.C. Campos, N. Cole, D.V. Dyk e mais 6. Proteomic analysis of dog tears for potential cancer markers. Res. Vet. Sci., 2008quem mais cita →
  6. 6C.Y. Chu, C.W. Poon, C.F. Pong e mais 2. Human normal tear proteome. Graefes Arch. Clin. Exp. Ophthalmol., 2009quem mais cita →
  7. 7S. Couture, M. Doucet, M. Moreau e mais 1. Topical effect of various agents on gelatinase activity in the tear film of normal dogs. Vet. Ophthalmol., 2006quem mais cita →
  8. 8G.A. De Souza, L.M.F. Godoy e M. Mann. Identification of 491 proteins in the tear fluid proteome reveals a large number of proteases and protease inhibitors. Genome Biology, 2006quem mais cita →
  9. 9A.M. Gachon, J. Richard e B. Dastugue. Human tears: normal protein pattern and individual protein determinations in adults. Curr. Eye Res., 1982quem mais cita →
  10. 10K.B. Green-Church, K.K. Nichols, N.M. Kleinholz e mais 2. Investigation of the human tear film proteome using multiple proteomic approaches. Molecular Vision, 2008quem mais cita →
  11. 11F.H. Grus, S.C. Joachim e N. Pfeiffer. Proteomics in ocular fluids: a review. Proteomics Clin. Appl., 2007quem mais cita →
  12. 12G.G. Gum, K.N. Gelatt e D.W. Esson. Physiology of the eye. Veterinary Ophthalmology, 2007quem mais cita →
  13. 13B.M. Ham, J.T. Jacob e R.B. Cole. Single eye analysis and contralateral eye comparison of tear proteins in normal and dry eye model rabbits by MALDI-ToF mass spectrometry using wax-coated target plates. Anal. Bioanal. Chem., 2007quem mais cita →
  14. 14D.T. Jones, D. Monroy e S. Pflugfelder. A novel method of tear collection: comparison of glass capillary micropippetes with porous polyester rods. Cornea, 1997quem mais cita →
  15. 15M. Markoulli, E. Papas, A. Petznick e mais 1. Validation of the Flush Method as an alternative to basal or reflex tear collection. Curr. Eye Res., 2011quem mais cita →
  16. 16S. Li, R. Sack, T. Vijmasi e mais 5. Antibody protein array analysis of the tear film cytokines. Optometry and Vision Science, 2008quem mais cita →
  17. 17K. Li, Z. Chen, F. Duan e mais 2. Quantification of tear proteins by SDS-PAGE with an internal standard protein: A new method with special reference to small volume tears. Graefes Arch. Clin. Exp. Ophthalmol., 2010quem mais cita →
  18. 18T.S. Lu, S.Y. Yiao, K. Lim e mais 2. Interpretation of biological and mechanical variations between the Lowry versus Bradford method for protein quantification. North Am. J. Med. Sci., 2010quem mais cita →
  19. 19F.J. Olliver, D.E. Brooks, G.B.V. Setten e mais 9. Profiles of matrix etalloproteinase activity in equine tear fluid during corneal healing in 10 horses with ulcerative keratitis. Vet. Ophtalmol., 2004quem mais cita →
  20. 20A. Petznick, M.D.M. Evans, M.C. Madigan e mais 3. A comparison of basaland eye-flush tears for the analysis of cat tear proteins. Acta Ophthalmologica, 2011quem mais cita →
1–20 de 25 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

5 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações