Química Nova2013

Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets

Ariane P. Cruz, Charise D. Bertol, Fábio S. Murakami, Rafael N. Pereira, Bruno R. Valente, Marcos A. S. Silva e Letícia S. Koester

em inglês

cita 8 obras

resumo

A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.

como citar · ABNT NBR 6023

CRUZ, Ariane P. et al. Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets. Química Nova, 2013. DOI: 10.1590/S0100-40422013000300010.

Referências

8 obras citadas

  1. 2Word Health Organization (WHO). World Malaria Report 2008. 2008quem mais cita →
  2. 3J. W. Tracy e L. T. Webster Jr.. Goodman & Gilman's the pharmacological basis of therapeutics. 2001quem mais cita →
  3. 5S. C. Sweetman. Martindale: The Extra Pharmacopeia. 2002quem mais cita →
  4. 13The United States Pharmacopeia. 2007quem mais cita →
  5. 16International Conference on Harmonization (ICH). Guideline on the Validation of Analytical Procedures: Text and Methodology Q2 (R1). 2005quem mais cita →
  6. 17Food and Drug Administration (FDA). Draft Guidance for Industry on Analytical Procedures and Methods Validation: Chemistry, Manufacturing, and Controls Documentation, Availability. Fed. Regist., 2000quem mais cita →
  7. 24Food and Drug Administration (FDA). Guidance for Industry on Dissolution Testing of Immediate Release Solid Oral Dosage Forms, Availability. Fed. Regist., 1997quem mais cita →
  8. 27Food and Drug Administration (FDA). Guidance for Industry: SUPAC-MR, Modified Release Solid Oral Dosage Forms; Scale-up and Post approval Changes for Chemistry. Manufacturing and Controls, 1997quem mais cita →