Radiologia Brasileira2016

Analysis of translational errors in frame-based and frameless cranial radiosurgery using an anthropomorphic phantom

Taynná Vernalha Rocha Almeida, Arno Lotar Cordova Junior, Pedro Argolo Piedade, Cintia Mara da Silva, Priscila Marins, Cristiane Maria Almeida, Gabriela R. Baseggio Brincas e Danyel Scheidegger Soboll

em inglês

cita 14 obras

resumo

Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.

como citar · ABNT NBR 6023

ALMEIDA, Taynná Vernalha Rocha et al. Analysis of translational errors in frame-based and frameless cranial radiosurgery using an anthropomorphic phantom. Radiologia Brasileira, 2016. DOI: 10.1590/0100-3984.2015.0053.

Referências

14 obras citadas

  1. 1AL Asher, SH Burri e WF Wiggins. A new treatment paradigm: neoadjuvant radiosurgery before surgical resection of brain metastases with analysis of local tumor recurrence. Int J Radiat Oncol Biol Phys, 2014quem mais cita →
  2. 2L Leksell. Stereotactic radiosurgery. J Neurol Neurosurg Psychiatry, 1983quem mais cita →
  3. 3M Lamba, JC Breneman e RE Warnick. Evaluation of image-guided positioning for frameless intracranial radiosurgery. Int J Radiat Oncol Biol Phys, 2009quem mais cita →
  4. 4MJ Murphy, SD Chang e IC Gibbs. Patterns of patient movement during frameless image-guided radiosurgery. Int J Radiat Oncol Biol Phys, 2003quem mais cita →
  5. 5N Ramakrishna, F Rosca e S Friesen. A clinical comparison of patient setup and intra-fraction motion using frame-based radio-surgery versus a frameless image-guided radiosurgery system for intracranial lesions. Radiother Oncol, 2010quem mais cita →
  6. 6Brainlab. Manual do usuário clínico. 2014quem mais cita →
  7. 7N Hayashi, Y Obata e Y Uchiyama. Assessment of spatial uncertainties in the radiotherapy process with the Novalis system. Int J Radiat Oncol Biol Phys, 2009quem mais cita →
  8. 8SD Karam, A Tai e A Strohl. Frameless fractionated stereotactic radiosurgery for vestibular schwannomas: a single-institution experience. Front Oncol, 2013quem mais cita →
  9. 9XQ Lu, A Mahadevan e G Mathiowitz. Frameless angiogrambased stereotactic radiosurgery for treatment of arteriovenous malformations. Int J Radiat Oncol Biol Phys, 2012quem mais cita →
  10. 10T Gevaert, D Verellen e K Tournel. Setup accuracy of the Novalis ExacTrac 6DOF system for frameless radiosurgery. Int J Radiat Oncol Biol Phys, 2012quem mais cita →
  11. 11D Schmidhalter, M Malthaner e EJ Born. Assessment of patient setup errors in IGRT in combination with a six degrees of freedom couch. Z Med Phys, 2014quem mais cita →
  12. 12H Badakhshi, T Barelkowski e P Wust. Intrafraction variations in linac-based image-guided radiosurgery of intracranial lesions. Cancer Radiother, 2013quem mais cita →
  13. 13RS Prabhu, A Dhabaan e WA Hall. Clinical outcomes for a novel 6 degrees of freedom image guided localization method for frameless radiosurgery for intracranial brain metastases. J Neurooncol, 2013quem mais cita →
  14. 14T Takakura, T Mizowaki e M Nakata. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system. Phys Med Biol, 2010quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações