Arquivos Brasileiros de Cardiologia2001
Enhancing longevity of pacemakers through reprogramming. Underutilization and cost-effectiveness
Antonio Luiz Pinho Ribeiro, Leonor Garcia Rincón, Bruna Guimarães Oliveira, Cleonice Carvalho Mota e Marco Túlio Bacarini Pires
em inglês
resumo
OBJECTIVE: This study was performed to observe the number of pacemakers that had never been reprogrammed after implantation, and the effect of optimised output programming on estimated longevity of pulse generators in patients with pacemaker METHODS: Sixty patients with Teletronics Reflex pacemakers were evaluated in a pacemaker clinic, from the time of the beginning of its activities, in June 1998, until March 1999. Telemetry was performed during the first clinic visit, and we observed how many pulse generators retained nominal output settings of the manufactures indicating the absence of reprogramming until that date. After evaluation of the capture threshold, reprogramming of pacemakers was performed with a safety margin of 2 to 2.5:1, and we compared the estimated longevity based on battery current at the manufacturer's settings with that based on settings achieved after reprogramming. RESULTS: In 95% of the cases, the original programmed setting was never reprogrammed before the patients attended the pacemaker clinic. Reprogramming the pacemaker prolonged estimated pulse generator life by 19.7±15.6 months (35.5%). CONCLUSION: The majority of the pacemakers evaluated had never been reprogrammed. Estimated pulse generator longevity can be prolonged significantly, using this simple, safe, efficacious, and cost-effective procedure.
como citar · ABNT NBR 6023
RIBEIRO, Antonio Luiz Pinho et al. Enhancing longevity of pacemakers through reprogramming. Underutilization and cost-effectiveness. Arquivos Brasileiros de Cardiologia, 2001. DOI: 10.1590/S0066-782X2001000600001.
Referências
18 obras citadas
- 1SS Barold e DG Zipes. Cardiac pacemakers and antiarrhythmic devices. Heart Disease: A Textbook of Cardiovascular Medicine, 1997quem mais cita →
- 2GH Crossley, DG Gayle e TW Simmons. Reprogramming pacemakers enhances longevity and is cost effective. Circulation, 1996quem mais cita →
- 3DF Underreker, RB Shepard, CL Schmidt e mais 2. Power sources for implantable pacemakers. Clinical Cardiac Pacing, 1995quem mais cita →
- 4KB Stokes e GN Kay. Artificial electric cardiac pacing. Clinical Cardiac Pacing, 1995quem mais cita →
- 5G Gregoratos, MD Cheitlin e A Conill. ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). J Am Coll Cardiol, 1998quem mais cita →
- 6AD Berstein, ME Irwin e V Parsonnet. Policy-conference report. antibradycardia-pacemaker follow-up: Effectiveness, needs and resources. Pacing Clin Electrophysiol, 1994quem mais cita →
- 7JC Griffin, TD Schuenemeyer e KR Hess. Pacemaker follow-up: Its role in the detection and correction of pacemaker system malfuntion. Pacing Clin Electrophysiol, 1986quem mais cita →
- 8W Irnich, E Kramer e R Muller. The progamming of cardiac pacemakers - wish and reality. Dtsch Med Wochenschr, 1991quem mais cita →
- 9SS Barold, K Stokes, CL Byrd e mais 1. Energy parametes in cardiac pacieng should be abandoned. Pacing Clin Electrophysiol, 1997quem mais cita →
- 10GOT Tyers e RR Brownlee. Power pulse generators, electrodes, and longevity. Prog Cardiovasc Dis, 1981quem mais cita →
- 11GH Crossley, JA Brinker e D Reynolds. Steroid elution improves the stimulation threshold in an active-fixation atrial permanent pacing lead: A randomized, controlled study. Model 4068 Investigators. Circulation, 1995quem mais cita →
- 12B Schwaab, G Frohlig e H Schwerdt. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity. Pacing Clin Electrophysiol, 1998quem mais cita →
- 13B Schwaab, H Schwerdt e A Heisel. Chronic ventricular pacing using an output amplitude of 1.0 Volts. Pacing Clin Electrophysiol, 1997quem mais cita →
- 14NJ Stamato, MF O'Toole, JG Fetter e mais 1. The safety and efficacy if chronic ventricular ventricular pacing at 16 volts using steroid eluting lead. Pacing Clin Electrophysiol, 1992quem mais cita →
- 15HH Klein e W Knake. Energy-conserving of VVI pacemakers: a telemetry-supported, long-term, follow-up study. Clin Cardiol, 1990quem mais cita →
- 16AM Gillis, DS McQuarrie e SL Wilson. The impact of pulse generator longevity on the long-term costs of cardiac pacing. Pacing Clin Electrophysiol, 1990quem mais cita →
- 17W Irnich. Pacemaker-related patient mortality. Pacing Clin Electrophysiol, 1999quem mais cita →
- 18M Clarke, B Liu e H Schuller. Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: a multicenter study. European Microny Study Group. Pacing Clin Electrophysiol, 1998quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda