ABSTRACT Optical coherence tomography is often used for detection of glaucoma as well as to monitor progression. This paper reviews the most common types of artifacts on the optical coherence tomography report that may be confused with glaucomatous damage. We mainly focus on anatomy-related artifacts in which the retinal layer segmentation and thickness measurements are correct. In such cases, the probability maps (also known as deviation maps) show abnormal (red and yellow) regions, which may mislead the clinician to assume disease is present. This is due to the anatomic variability of the individual, and the normative database must be taken into account.
como citar · ABNT NBR 6023
LESHNO, Ari et al. Identifying and understanding optical coherence tomography artifacts that may be confused with glaucoma. Revista Brasileira de Oftalmologia, 2022. DOI: 10.37039/1982.8551.20220103.
Referências
50 obras citadas
- 1PR Lichter. Variability of expert observers in evaluating the optic disc. Trans Am Ophthalmol Soc, 1976quem mais cita →
- 2R Cooper, V Alder e I Constable. Measurement vs. judgement of cup-disc ratios: statistical evaluation of intraobserver and interobserver error. Glaucoma, 1982quem mais cita →
- 3JM Tielsch, J Katz, HA Quigley e mais 2. Intraobserver and interobserver agreement in measurement of optic disc characteristics. Ophthalmology, 1988quem mais cita →
- 4LS Abrams, IU Scott, GL Spaeth e mais 2. Agreement among optometrists, ophthalmologists, and residents in evaluating the optic disc for glaucoma. Ophthalmology, 1994quem mais cita →
- 5LM Zangwill, S Shakiba, J Caprioli e mais 1. Agreement between clinicians and a confocal scanning laser ophthalmoscope in estimating cup/disk ratios. Am J Ophthalmol, 1995quem mais cita →
- 6JS Schuman, T Pedut-Kloizman, E Hertzmark e mais 3. Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology, 1996quem mais cita →
- 7EZ Blumenthal, JM Williams, RN Weinreb e mais 3. Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography. Ophthalmology, 2000quem mais cita →
- 8P Carpineto, M Ciancaglini, E Zuppardi e mais 3. Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes. Ophthalmology, 2003quem mais cita →
- 9DL Budenz, MJ Fredette, WJ Feuer e mais 1. Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes. Ophthalmology, 2008quem mais cita →
- 10JC Mwanza, RT Chang, DL Budenz e mais 3. Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with Cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci, 2010quem mais cita →
- 11SJ Langenegger, J Funk e M Töteberg-Harms. Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci, 2011quem mais cita →
- 12GT Chong e RK Lee. Glaucoma versus red disease: imaging and glaucoma diagnosis. Curr Opin Ophthalmol, 2012quem mais cita →
- 13JJ Chen e RH Kardon. Avoiding clinical misinterpretation and artifacts of optical coherence tomography analysis of the optic nerve, retinal nerve fiber layer, and ganglion cell layer. J Neuroophthalmol, 2016quem mais cita →
- 14DC Hood, S La Bruna, E Tsamis e mais 3. Detecting glaucoma with only OCT: Implications for the clinic, research, screening, and AI development. Prog Retin Eye Res, 2022quem mais cita →
- 15DC Hood. Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT). Prog Retin Eye Res, 2017quem mais cita →
- 16S La Bruna, A Rai, G Mao e mais 3. The OCT RNFL probability map and artifacts resembling glaucomatous damage. Transl Vis Sci Technol, 2022quem mais cita →
- 17DC Hood, B Fortune, SN Arthur e mais 3. Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography. J Glaucoma, 2008quem mais cita →
- 18DC Hood, JA Salant, SN Arthur e mais 2. The location of the inferior and superior temporal blood vessels and interindividual variability of the retinal nerve fiber layer thickness. J Glaucoma, 2010quem mais cita →
- 19K Qiu, J Schiefer, J Nevalainen e mais 2. Influence of the retinal blood vessel topography on the variability of the retinal nerve fiber bundle trajectories in the human retina. Invest Ophthalmol Vis Sci, 2015quem mais cita →
- 20JL Hougaard, C Ostenfeld, A Heijl e mais 1. Modelling the normal retinal nerve fibre layer thickness as measured by Stratus optical coherence tomography. Graefes Arch Clin Exp Ophthalmol, 2006quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda