Revista Brasileira de Oftalmologia2013

Best waveform score for diagnosing keratoconus

Allan Luz, Bruno Machado Fontes, Bernardo Lopes, Isaac Ramos, Fernando Faria Correia, Paulo Schor e Renato Ambrósio Jr.

em inglês

cita 25 obras, 1 no acervo

resumo

PURPOSE: To test whether corneal hysteresis (CH) and corneal resistance factor (CRF) can discriminate between keratoconus and normal eyes and to evaluate whether the averages of two consecutive measurements perform differently from the one with the best waveform score (WS) for diagnosing keratoconus. METHODS: ORA measurements for one eye per individual were selected randomly from 53 normal patients and from 27 patients with keratoconus. Two groups were considered the average (CH-Avg, CRF-Avg) and best waveform score (CH-WS, CRF-WS) groups. The Mann-Whitney U-test was used to evaluate whether the variables had similar distributions in the Normal and Keratoconus groups. Receiver operating characteristics (ROC) curves were calculated for each parameter to assess the efficacy for diagnosing keratoconus and the same obtained for each variable were compared pairwise using the Hanley-McNeil test. RESULTS: The CH-Avg, CRF-Avg, CH-WS and CRF-WS differed significantly between the normal and keratoconus groups (p<0.001). The areas under the ROC curve (AUROC) for CH-Avg, CRF-Avg, CH-WS, and CRF-WS were 0.824, 0.873, 0.891, and 0.931, respectively. CH-WS and CRF-WS had significantly better AUROCs than CH-Avg and CRF-Avg, respectively (p=0.001 and 0.002). CONCLUSION: The analysis of the biomechanical properties of the cornea through the ORA method has proved to be an important aid in the diagnosis of keratoconus, regardless of the method used. The best waveform score (WS) measurements were superior to the average of consecutive ORA measurements for diagnosing keratoconus.

como citar · ABNT NBR 6023

LUZ, Allan et al. Best waveform score for diagnosing keratoconus. Revista Brasileira de Oftalmologia, 2013. DOI: 10.1590/S0034-72802013000600002.

Referências

25 obras citadas · 1 no acervo

  1. 1YS Rabinowitz. Keratoconus. SurvOphthalmol, 1998
  2. 2X Li, YS Rabinowitz, K Rasheed e mais 1. Longitudinal study of the normal eyes in unilateral keratoconus patients. Ophthalmology, 2004quem mais cita →
  3. 3S Shah, M Laiquzzaman, R Bhojwani e mais 2. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci., 2007quem mais cita →
  4. 5DA Luce. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg., 2005quem mais cita →
  5. 6DZ Reinstein, M Gobbe e TJ Archer. Ocular biomechanics: measurementparametersand terminology. J Refract Surg., 2011quem mais cita →
  6. 7AK Lam, D Chen e J Tse. The Usefulness of Waveform Score from the Ocular Response Analyzer. Optom Vis Sci., 2010quem mais cita →
  7. 8R Jr Ambrósio, LP Nogueira, DL Caldas e mais 3. Evaluation of corneal shape and biomechanics before LASIK. IntOphthalmolClin, 2011quem mais cita →
  8. 9K Zadnik, JT Barr, TB Edrington e mais 3. Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. InvestOphthalmol Vis Sci., 1998quem mais cita →
  9. 10DA Luce. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J CataractRefractSurg, 2005quem mais cita →
  10. 11D Ortiz, D Piñero, MH Shabayek e mais 2. Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J CataractRefractSurg, 2007quem mais cita →
  11. 12S Shah e M Laiquzzaman. Comparison of corneal biomechanics in pre and post-refractive surgery and keratoconic eyes by Ocular Response Analyser. Cont Lens Anterior Eye, 2009quem mais cita →
  12. 13D. Luce. Methodology for cornea compensated IOP and corneal resistance factor for the Reichert Ocular Response Analyzer. Invest Ophthalmol Vis Sci, 2006quem mais cita →
  13. 14ER DeLong, DM DeLong e DL Clarke-Pearson. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics, 1988quem mais cita →
  14. 15JA Hanley e BJ McNeil. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology, 1982quem mais cita →
  15. 16NG Congdon, AT Broman, K Bandeen-Roche e mais 2. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol., 2006quem mais cita →
  16. 17GS Ang, F Bochmann, J Townend e mais 1. Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma. J Glaucoma, 2008quem mais cita →
  17. 18G Mangouritsas, G Morphis, S Mourtzoukos e mais 1. Association between corneal hysteresis and central corneal thickness in glaucomatous and non-glaucomatous eyes. Acta Ophthalmol, 2009quem mais cita →
  18. 19K Kamiya, K Shimizu e F Ohmoto. Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in situ keratomileusis. Cornea, 2009quem mais cita →
  19. 20A Lam, D Chen, R Chiu e mais 1. Comparison of IOP measurements between ORA and GAT in normal Chinese. Optom Vis Sci., 2007quem mais cita →
  20. 21AP Wells, DF Garway-Heath, A Poostchi e mais 3. Corneal hysteresis but not corneal thickness correlates with optic nerve surfacecompliance in glaucoma patients. Invest Ophthalmol Vis Sci., 2008quem mais cita →
1–20 de 25 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações