Dose distribution evaluation in oncological radiotherapy treatments is an outstanding problem that requires sophisticated computing technologies to optimize the clinical results (i.e. increase the dose to the tumour and reduce the dose to the healthy tissues). Nowdays, dose calculation algorithms based on the Monte Carlo method are generally regarded as the most accurate tools for radiotherapy. The flexibility of the GEANT4 (GEometry ANd Tracking) Monte Carlo particle transport simulation code allows a wide range of applications, from high-energy to medical physics. In order to disseminate and encourage the use of Monte Carlo method in oncological radiotherapy, a software package based on the GEANT4 Monte Carlo toolkit has been developed. The developed package (MedLinac2) allows to simulate in an adequate flexible way a linear accelerator for radiotherapy and to evaluate the dose distributions.
como citar · ABNT NBR 6023
CACCIA, Barbara; ANDENNA, Claudio; CIRRONE, Giuseppe Antonio Pablo. MedLinac2: a GEANT4 based software package for radiotherapy. Annali dell'Istituto Superiore di Sanità, 2010. DOI: 10.4415/ANN_10_02_11.
Referências
11 obras citadas
- 1GP Delaney, S Jacob, C Featherstone e mais 1. The role of radiotherapy in cancer treatment: estimating optimal utilisation from a review of evidence-based clinical guidelines. Cancer, 2005quem mais cita →
- 2X G Xu, B Bednarz e H Paganetti. A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction phases. Phys Med Biol, 2008quem mais cita →
- 3IJ Chetty. Report of the AAPM Task Group No.105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys, 2007quem mais cita →
- 4E Spezi e G Lewis. An overview of Monte Carlo treatment planning for radiotherapy. Rad Prot Dos, 2008quem mais cita →
- 5GEANT4 Collaboration. GEANT4 developments and applications. IEEE Transactions on Nuclear Science, 2007quem mais cita →
- 6F Foppiano, B Mascialino, MG Pia e mais 1. GEANT4 simulation of an accelerator head for intensity modulated radiotherapy. Proceedings of The Monte Carlo method: versatility unbounded in a dynamic computing world, 2005quem mais cita →
- 7GAP Cirrone, G Cuttone, S Guatelli e mais 6. Implementation of a new Monte Carlo: GEANT4 simulation tool for the development of a proton therapy beam line and verification of the related dose distributions. IEEE Transactions on Nuclear Science, 2005quem mais cita →
- 8B Caccia, G Frustagli, M Mattia e mais 5. Lung densities in different respiratory phases: a dosimetric study based on GEANT4 simulation and GafChromic films. Proceedings of thequem mais cita →
- 9A Fogliata, E Vanetti, D Albers e mais 5. On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with MonteCarlo calculations. Phys Med Biol, 2007quem mais cita →
- 10B Caccia, M Mattia, G Amati e mais 7. Monte Carlo in radiotherapy: experience in a distributed computational environment. JPhys Conference Series, 2007quem mais cita →
- 11V Ardizzone, R Barbera e GAP Cirrone. Dose distribution verifications in medical physics: the results obtained using GEANT4 and GRID technology. Proceedings of final workshop of grid projects, 2009quem mais cita →