Annali dell'Istituto Superiore di Sanità2010

Hardware performance assessment recommendations and tools for baropodometric sensor systems

Claudia Giacomozzi

em inglês

citado por 3 artigoscita 30 obras

resumo

Accurate plantar pressure measurements are mandatory in both clinical and research contexts. Differences in accuracy, precision, reliability of pressure measurement devices (PMDs) prevented so far the onset of standardization processes and of reliable reference datasets. The Italian National Institute of Health (ISS) approved and conducted a scientific project aimed to design, validate and implement dedicated testing methods for both in-factory and on-the-field PMD assessment. A general-purpose experimental set-up was built, complete and suitable for the assessment of PMDs based on different sensor technology, electronic conditioning and mechanical solutions. Preliminary assessments have been conducted on 5 commercial PMDs. The study lead to the definition of: i) an appropriate set of instruments and procedures for PMD technical assessment; ii) a minimum set of significant parameters for the technical characterization of the PMD performance; iii) some recommendations to both manufacturers and end users for an appropriate use in clinics and in research context

como citar · ABNT NBR 6023

GIACOMOZZI, Claudia. Hardware performance assessment recommendations and tools for baropodometric sensor systems. Annali dell'Istituto Superiore di Sanità, 2010. DOI: 10.4415/ANN_10_02_09.

Referências

30 obras citadas

  1. 1AB Putti, GP Arnold, LA Cochrane e mais 1. Normal pressure values and repeatability of the Emed ST4 system. Gait & Posture, 2008quem mais cita →
  2. 2C Alvarez, M De Vera, H Chhina e mais 1. Normative data for the dynamic pedobarographic profiles of children. Gait & Posture, 2008quem mais cita →
  3. 3N Ghani Zadeh Hesar, A Van Ginckel, AM Cools e mais 4. A prospective study on gait-related intrinsic risk factors for lower leg overuse injuries. Br J Sports Med, 2009quem mais cita →
  4. 4Y Thijs, D Van Tiggelen, P Roosen e mais 2. A prospective study on gait-related intrinsic risk factors for patellofemoral pain. Clin J Sport Med, 2007quem mais cita →
  5. 5A De Cock, D De Clercq, T Willemsb e mais 1. Temporal characteristics of foot roll-over during barefoot jogging: reference data for young adults. Gait & Posture, 2005quem mais cita →
  6. 6A Hallemans, D De Clercq, S Van Dongen e mais 1. Changes in foot-function parameters during the first 5 months after the onset of independent walking: a longitudinal follow-up study. Gait & Posture, 2006quem mais cita →
  7. 7K Bosch, J Gerss e D Rosenbaum. Preliminary normative values for foot loading parameters of the developing child. Gait & Posture, 2007quem mais cita →
  8. 8C Bertsch, H Unger, W Winkelmann e mais 1. Evolution of early walking patterns from plantar pressure distribution measurements: First year results of 42 children. Gait & Posture, 2004quem mais cita →
  9. 9E Hennig e D Rosenbaum. Pressure distribution patterns under the feet of children in comparison with adults. Foot Ankle, 1991quem mais cita →
  10. 10MP Solano, LM Prieto, JC Varon e mais 2. Ethnic differences in plantar pressures in diabetic patients with peripheral neuropathy. Diabetic Medicine, 2008quem mais cita →
  11. 11C Giacomozzi e F Martelli. Peak pressure curve: an effective parameter for early detection of foot functional impairments in diabetic patients. Gait & Posture, 2006quem mais cita →
  12. 12JS Wrobel, RT Crews e JE Connolly. Clinical factors associated with a conservative gait pattern in older male veterans with diabetes. J of Foot and Ankle Research, 2009quem mais cita →
  13. 13J Cobb e DJ Claremont. Transducers for foot pressure measurement: survey of recent development. Med Biol Eng Comput, 1995quem mais cita →
  14. 14KJ Roy. Force, pressure and motion measurements in the foot: current concepts. Clin Podiatr Med Surg, 1988quem mais cita →
  15. 15M Lord, DP Reynolds e JR Hughes. Foot pressure measurement: a review of clinical findings. J Biomed Eng, 1986quem mais cita →
  16. 16C Giacomozzi. Appropriateness of plantar pressure measurement devices: a comparative technical assessment. Gait & Posture, 2010quem mais cita →
  17. 17C Giacomozzi, G De Angelis, M Paolizzi e mais 2. Pneumatic test device for the accurate assessment of pressure sensors. IFMBE Proceedings 25/9, 2009quem mais cita →
  18. 18H Hillstrom, C Giacomozzi, M Lenhoff e mais 5. Accuracy of the novel emed®-x and Tekscan matscan plantar pressure measurement systems. 2008quem mais cita →
  19. 19JM Brimacombe, DR Wilson, AJ Hodgson e mais 2. Effect of calibration method on Tekscan sensor accuracy. J Biomech Eng, 2009quem mais cita →
  20. 20C Giacomozzi, F Martelli, A Nagel e mais 2. Cluster analysis to classify gait alterations in rheumatoid arthritis using peak pressure curves. Gait & Posture, 2009quem mais cita →
1–20 de 30 obras citadas

Quem cita esta obra

3 artigos do acervo

ano a anomais citada em 2010 · 1 artigo
Mais citada em 2010, com 1 artigo.
  • 2010: citada em 1 artigo
  • 2012: citada em 1 artigo
  • 2020: citada em 1 artigo

quem fala desta obra

9 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações