Arquivos de Neuro-Psiquiatria2025
Testing magnetic resonance imaging parameters to predict pituitary macroadenoma consistency
Thaylla Maybe Bedinot da Conceição, Jaisa Quedi Araújo da Silva, Matheus de Lima Ruffini, Adolfo Moraes de Souza, Fabiano Reis, Ápio Cláudio Martins Antunes, Marino Muxfeldt Bianchin e Juliana Ávila Duarte
em inglês
resumo
Abstract Background Pituitary macroadenomas (PMAs) are frequently encountered tumors, predominantly characterized as soft and easily resectable during neurosurgery. In contrast, fibrous PMAs present difficulties during surgical removal. Therefore, the ability to predict the consistency of PMAs preoperatively could enhance surgical planning. Objective To evaluate the ability of conventional T2-weighted imaging (T2WI) to predict PMA consistency by comparing isolated tumor signal intensity with the adenoma-to-middle cerebellar peduncle (ACP) ratio. Methods Magnetic resonance imaging (MRI) scans from 45 patients with PMAs were independently reviewed by 3 blinded radiologists. For each case, the signal intensity (SI) of the adenoma and of the middle cerebellar peduncle was measured, and the ACP ratio (SIadenoma/SIpeduncle) was calculated. Tumor consistency (soft or fibrous) was determined intraoperatively by a single neurosurgeon. Results Intraoperative assessment classified 29 PMAs (64.4%) as soft and 16 (35.6%) as fibrous. Isolated adenoma SI on T2WI differed significantly between soft and fibrous tumors (p = 0.013), while the ACP ratio demonstrated stronger discriminatory power (p < 0.0001). The receiver operating characteristic (ROC) curve yielded an area under the curve of 0.939 for the ACP ratio. Threshold values > 1.59 were highly predictive of soft tumors (sensitivity 72.4%; specificity 100.0%), whereas values < 1.27 were associated with fibrous tumors (sensitivity 100.0%; specificity 37.5%). Conclusion Although isolated adenoma SI on T2WI showed statistical significance, it was not sufficient for consistent preoperative prediction of tumor consistency. The ACP ratio provided superior accuracy and clinical utility, supporting its role as a noninvasive imaging biomarker to enhance preoperative assessment and surgical planning in patients with pituitary macroadenomas.
como citar · ABNT NBR 6023
CONCEIÇÃO, Thaylla Maybe Bedinot da et al. Testing magnetic resonance imaging parameters to predict pituitary macroadenoma consistency. Arquivos de Neuro-Psiquiatria, 2025. DOI: 10.1055/S-0045-1813239.
Referências
19 obras citadas
- 1KA Smith, JD Leever e RB Chamoun. Prediction of consistency of pituitary adenomas by Magnetic Resonance Imaging. J Neurol Surg B Skull Base, 2015quem mais cita →
- 2JD Hughes, N Fattahi, J Van Gompel e mais 3. Magnetic resonance elastography detects tumoral consistency in pituitary macroadenomas. Pituitary, 2016quem mais cita →
- 3RB Snow, CE Johnson, S Morgello e mais 2. Is magnetic resonance imaging useful in guiding the operative approach to large pituitary tumors?. Neurosurgery, 1990quem mais cita →
- 4V Garcia-Navarro, G Lancman, A Guerrero-Maldonado e mais 2. Use of a side-cutting aspiration device for resection of tumors during endoscopic endonasal approaches. Neurosurg Focus, 2011quem mais cita →
- 5J Hardy. Transsphenoidal hypophysectomy. J Neurosurg, 1971quem mais cita →
- 6AG Chacko e MJ Chandy. Transsphenoidal line of vision on MRI for pituitary tumor surgery. Neurol India, 2002quem mais cita →
- 7K Saito, A Kuwayama, N Yamamoto e mais 1. The transsphenoidal removal of nonfunctioning pituitary adenomas with suprasellar extensions: the open sella method and intentionally staged operation. Neurosurgery, 1995quem mais cita →
- 8G Zada, R Du e ER Laws Jr. Defining the "edge of the envelope": patient selection in treating complex sellar-based neoplasms via transsphenoidal versus open craniotomy. J Neurosurg, 2011quem mais cita →
- 9L Wei, SA Lin, K Fan e mais 3. Relationship between pituitary adenoma texture and collagen content revealed by comparative study of MRI and pathology analysis. Int J Clin Exp Med, 2015quem mais cita →
- 10C Yang, H Zhang, HJ Wang e mais 3. [Controlled pathological study and preoperative MRI evaluation of the consistency of pituitary adenomas]. Ai Zheng, 2002quem mais cita →
- 11T Iuchi, N Saeki, M Tanaka e mais 2. MRI prediction of fibrous pituitary adenomas. Acta Neurochir (Wien), 1998quem mais cita →
- 12H Naganuma, E Satoh e H Nukui. Technical considerations of transsphenoidal removal of fibrous pituitary adenomas and evaluation of collagen content and subtype in the adenomas. Neurol Med Chir (Tokyo), 2002quem mais cita →
- 13S Chakrabortty, S Oi, M Yamaguchi e mais 2. Growth hormone-producing pituitary adenomas: MR characteristics and pre- and postoperative evaluation. Neurol Med Chir (Tokyo), 1993quem mais cita →
- 14B Bahuleyan, L Raghuram, V Rajshekhar e mais 1. To assess the ability of MRI to predict consistency of pituitary macroadenomas. Br J Neurosurg, 2006quem mais cita →
- 15C Suzuki, M Maeda e K Hori. Apparent diffusion coefficient of pituitary macroadenoma evaluated with line-scan diffusion-weighted imaging. J Neuroradiol, 2007quem mais cita →
- 16A Pierallini, F Caramia e C Falcone. Pituitary macroadenomas: preoperative evaluation of consistency with diffusion-weighted MR imaging--initial experience. Radiology, 2006quem mais cita →
- 17OM Mahmoud, A Tominaga e VJ Amatya. Role of PROPELLER diffusion-weighted imaging and apparent diffusion coefficient in the evaluation of pituitary adenomas. Eur J Radiol, 2011quem mais cita →
- 18R Fahlbusch, R Niston e M Buchfelder. Magnetic resonance imaging [MRI] in the preoperative diagnosis of pituitary adenomas: a comparison with CT. Advances in pituitary adenoma research: proceedings of the fourth European Workshop on Pituitary Adenomas, 1998quem mais cita →
- 19AK Thotakura, MR Patibandla, MK Panigrahi e mais 1. Is it really possible to predict the consistency of a pituitary adenoma preoperatively?. Neurochirurgie, 2017quem mais cita →