Arquivos de Neuro-Psiquiatria2017
Critical analysis on the present methods for brain volume measurements in multiple sclerosis
Yara Dadalti Fragoso, Paulo Roberto Willie, Marcus Vinicius Magno Goncalves e Joseph Bruno Bidin Brooks
em inglês
citado por 1 artigocita 59 obras
resumo
ABSTRACT Objective The treatment of multiple sclerosis (MS) has quickly evolved from a time when controlling clinical relapses would suffice, to the present day, when complete disease control is expected. Measurement of brain volume is still at an early stage to be indicative of therapeutic decisions in MS. Methods This paper provides a critical review of potential biases and artifacts in brain measurement in the follow-up of patients with MS. Results Clinical conditions (such as hydration or ovulation), time of the day, type of magnetic resonance machine (manufacturer and potency), brain volume artifacts and different platforms for volumetric assessment of the brain can induce variations that exceed the acceptable physiological rate of annual loss of brain volume. Conclusion Although potentially extremely valuable, brain volume measurement still has to be regarded with caution in MS.
como citar · ABNT NBR 6023
FRAGOSO, Yara Dadalti et al. Critical analysis on the present methods for brain volume measurements in multiple sclerosis. Arquivos de Neuro-Psiquiatria, 2017. DOI: 10.1590/0004-282X20170072.
Referências
59 obras citadas
- 1E Havrdova, S Galetta, D Stefoski e mais 1. Freedom from disease activity in multiple sclerosis. Neurology, 2010quem mais cita →
- 2R Gold, HP Hartung, M Stangel e mais 2. Therapeutic goals of baseline and escalation therapy for relapsing-remitting multiple sclerosis. Aktuelle Neurol, 2012quem mais cita →
- 3L Kappos, N De Stefano, MS Freedman e mais 3. Inclusion of brain volume loss in a revised measure of ‘no evidence of disease activity’ (NEDA-4) in relapsing-remitting multiple sclerosis. Mult Scler, 2016quem mais cita →
- 4N De Stefano, ML Stromillo, A Giorgio e mais 3. Establishing pathological cut-offs of brain atrophy rates in multiple sclerosis. J Neurol Neurosurg Psychiatry, 2016quem mais cita →
- 5MP Sormani, DL Arnold e N De Stefano. Treatment effect on brain atrophy correlates with treatment effect on disability in multiple sclerosis. Ann Neurol, 2014quem mais cita →
- 6JF Kurtzke. Rating neurologic impairment in multiple sclerosis: an expanded disability status scale (EDSS). Neurology, 1983quem mais cita →
- 7J Jovicich, S Czanner, X Han e mais 3. MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths. Neuroimage, 2009quem mais cita →
- 8H Takao, N Hayashi e K Ohtomo. Effect of scanner in longitudinal studies of brain volume changes. J Magn Reson Imaging, 2011quem mais cita →
- 9J Jovicich, S Czanner, D Greve e mais 3. Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data. Neuroimage, 2006quem mais cita →
- 10X Han, J Jovicich, D Salat e mais 3. Reliability of MRI-derived measurements of human cerebral cortical thickness: the effects of field strength, scanner upgrade and manufacturer. Neuroimage, 2006quem mais cita →
- 11DP Streitbürger, A Pampel, G Krueger e mais 3. Impact of image acquisition on voxel-based-morphometry investigations of age-related structural brain changes. Neuroimage, 2014quem mais cita →
- 12R Chu, S Tauhid, BI Glanz e mais 3. Whole Brain Volume Measured from 1.5T versus 3T MRI in healthy subjects and patients with multiple sclerosis. J Neuroimaging, 2016quem mais cita →
- 13HJ Huppertz, J Kröll-Seger, S Klöppel e mais 2. Intra- and interscanner variability of automated voxel-based volumetry based on a 3D probabilistic atlas of human cerebral structures. Neuroimage, 2010quem mais cita →
- 14H Takao, N Hayashi e K Ohtomo. Effects of the use of multiple scanners and of scanner upgrade in longitudinal voxel-based morphometry studies. J Magn Reson Imaging, 2013quem mais cita →
- 15M Reuter, MD Tisdall, A Qureshi e mais 3. Head motion during MRI acquisition reduces gray matter volume and thickness estimates. Neuroimage, 2015quem mais cita →
- 16Z Caramanos, VS Fonov, SJ Francis e mais 3. Gradient distortions in MRI: characterizing and correcting for their effects on SIENA-generated measures of brain volume change. Neuroimage, 2010quem mais cita →
- 17JB Brewer. Fully-automated volumetric MRI with normative ranges: translation to clinical practice. Behav Neurol, 2009quem mais cita →
- 18A Vidal-Jordana, J Sastre-Garriga, F Pérez-Miralles e mais 3. Early brain pseudoatrophy while on natalizumab therapy is due to white matter volume changes. Mult Scler, 2013quem mais cita →
- 19R Conforti, M Cirillo, PP Saturnino e mais 3. Dilated Virchow-Robin spaces and multiple sclerosis: 3 T magnetic resonance study. Radiol Med (Torino), 2014quem mais cita →
- 20M Battaglini, M Jenkinson e N De Stefano. Evaluating and reducing the impact of white matter lesions on brain volume measurements. Hum Brain Mapp, 2012quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
4 pessoas- Renan Barros DOMINGUES1 artigo · 2019
- Gustavo Bruniera Peres FERNANDES1 artigo · 2019
- Fernando Brunale Vilela de Moura LEITE1 artigo · 2019
- Carlos SENNE1 artigo · 2019
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda