Arquivos de Neuro-Psiquiatria2005

Clip readjustment in aneurysm surgery after flow evaluation using the ultrasonic perivascular probe: case report

Walter J. Fagundes-Pereyra, William E. Hoffman, Mukesh Misra e Fady T. Charbel

em inglês

citado por 2 artigoscita 17 obras

resumo

Occlusion or stenosis of a parent vessel or its distal branches is a major cause of poor patient outcome after cerebral aneurysm surgery. Despite great attempts to preserve patency at the time of clip application, intraoperative visual observation may not reveal arterial compromise or occlusion. Quantitative measurement of blood flow in cerebral vessels during aneurysm surgery can help prevent ischaemia and improve patient outcome. We report a case of a large complex middle cerebral artery (MCA) aneurysm in which perivascular microflow probes were used to measure blood flow quantitatively in MCA and its branches before and after aneurysm clipping. Following aneurysm clipping, blood flow in the MCA branches were significantly reduced to less than its initial baseline value with occlusion of the inferior M2 segment. Prompt detection of compromised blood flow gave the surgeon the opportunity to adjust the clip. This adjustment was performed several times until restore MCA flow to its preclipping values. Intraoperative quantitative vessel-flow measurements were safe and may have prevented cerebral ischaemia and neurological deficit to this patient.

como citar · ABNT NBR 6023

FAGUNDES-PEREYRA, Walter J. et al. Clip readjustment in aneurysm surgery after flow evaluation using the ultrasonic perivascular probe: case report. Arquivos de Neuro-Psiquiatria, 2005. DOI: 10.1590/S0004-282X2005000200028.

Referências

17 obras citadas

  1. 1JE Bailes, LS Tantuwaya, T Fukushima e mais 2. Intraoperative microvascular Doppler sonography in aneurysm surgery. Neurosurgery, 1997quem mais cita →
  2. 2FT Charbel, G Gonzales-Portilho, WE Hoffman e mais 2. Quantitative assessment of vessel flow integrity for aneurysm surgery. J Neurosurg, 1999quem mais cita →
  3. 3FT Charbel, WE Hoffman, M Misra e mais 2. Role of a perivascular ultrasonic micro-flow probe in aneurysm surgery. Neurol Med Chir, 1998quem mais cita →
  4. 4R Stendel, T Pietilã, AAA Hassan e mais 2. Intraoperative microvascular Doppler ultrsonography in cerebral aneurysm. J Neurol Neurosurg Psychiatry, 2000quem mais cita →
  5. 5RL Macdonald, MC Wallace e JRW Kestle. Role of angiography following aneurysm surgery. J Neurosurg, 1993quem mais cita →
  6. 6TC Origitano, K Schwartz e D Anderson. Optimal clip application and intraoperative angiography for intensive care aneurysms. Surg Neurol, 1999quem mais cita →
  7. 7TD Payner, TG Horner, TJ Leipzig e mais 3. Role of intraoperative angiography in the surgical treatment of cerebral aneurysms. J Neurosurg, 1998quem mais cita →
  8. 8NA Martin, J Bentson e F Viñuela. Intraoperative digital subtraction angiography and the surgical treatment of intracranial aneurysms and vascular malformations. J Neurosurg, 1990quem mais cita →
  9. 9DL Barrow, KL Boyer e GJ Joseph. Intraoperative angiography in the management of neurovascular disorders. Neurosurgery, 1992quem mais cita →
  10. 10TD Alexander, RL Macdonald e B Weir. Intraoperative angiography in cerebral aneurysm surgery: a prospective study of 100 craniotomies. Neurosurgery, 1996quem mais cita →
  11. 11CP Derdeyn, CJ Moran, DT III Cross e mais 2. Intracranial aneurysm: anatomic factors that predict the usefulness of intraoperative angiography. Radiology, 1997quem mais cita →
  12. 12MS D' Almeida, C Gaudin e D Lebec. Validation of 1- and 2-mm transit time ultrasound flow probes on mesenteric artery and aorta of rats. Am J Physiol, 1995quem mais cita →
  13. 13JC Hartman, DA Olszanske e TG Hullinger. In vivo validation of a transit-time ultrasonic volume flow meter. J Pharmacol Toxicol Methods, 1994quem mais cita →
  14. 14A Lundell, D Bergqvist e E Maattsson. Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study. Clin Physiol, 1993quem mais cita →
  15. 15WJ Welch, X Deng e H Snellen. Validation of miniature ultrasonic transit-time flow probes for measurement of renal blood flow in rats. Am J Physiol, 1995quem mais cita →
  16. 16C Wen, M Li e JA Whitworth. Validation of transonic small animal flowmeter for measurement of cardiac output and regional blood flow in the rat. J Cardiovasc Pharmacol, 1996quem mais cita →
  17. 17N Nakayama, S Kuroda, K Houkin e mais 2. Intraoperative measurement of arterial blood flow using a transit time flowmeter: monitoring of hemodynamic changes during cerebrovascular surgery. Acta Neurochir, 2001quem mais cita →

Quem cita esta obra

2 artigos do acervo

ano a anomais citada em 2008 · 1 artigo
Mais citada em 2008, com 1 artigo.
  • 2008: citada em 1 artigo
  • 2017: citada em 1 artigo

quem fala desta obra

15 pessoas
ver as 15 pessoas e os artigos →

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações