Arquivos de Neuro-Psiquiatria2001
Comparison between the NASCET method and subjective visual impression in the evaluation of internal carotid artery stenosis
Marco Oliveira Py, Charles André e Feliciano Silva de Azevedo
em inglês
resumo
OBJECTIVE: To evaluate the accuracy of subjective visual impression (SVI) of an experienced neuro-radiologist in the measurement of the degree of internal carotid artery (IC) stenosis evaluated by digital angiography (DGA). METHOD: Ten symptomatic patients with internal carotid stenosis greater than 70% in a previous duplex scan were submitted to DGA. The degree of stenosis in both sides (symptomatic and asymptomatic) were evaluated by the same neuro-radiologist who gave his SVI and applied the NASCET method immediately after. Both methods were compared using the intraclass correlation coeficient (r) and its 95% confidence interval (95% ci). For each method, the sample (20 ICs) was also divided in surgical (stenosis between 70 and 99%) and non surgical ICs, using kappa concordance coeficient (k) to compare the results. RESULTS: The results comparing the 20 values obtained by each method are: r = 0.90 (95% ci: 0.77 -- 0.96). Dividing the sample in surgical and non surgical ICs, k = 0.857, p < 0.0001; sensitivity = 100% (39.6% - 100%); specificity = 93.8% (67.7% - 99.7%); positive predictive value = 80% (29.9% - 98.9%); negative predictive value = 100% (74,7% - 100%). CONCLUSION: The SVI may be used by at least some experienced neuroradiologists as a preliminary tool to evaluate the degree of IC stenosis with DGA, but a standardised and well established method should be routinely performed.
como citar · ABNT NBR 6023
PY, Marco Oliveira; ANDRÉ, Charles; AZEVEDO, Feliciano Silva de. Comparison between the NASCET method and subjective visual impression in the evaluation of internal carotid artery stenosis. Arquivos de Neuro-Psiquiatria, 2001. DOI: 10.1590/S0004-282X2001000500003.
Referências
20 obras citadas · 1 no acervo
- 1JT Robertson. Carotid endarterectomy: a saga of clinical science, personalities, and evolving technology. The Willis lecture. Stroke, 1998quem mais cita →
- 2PB Gorelick. Carotid endarterectomy: where do we draw the line?. Stroke, 1999quem mais cita →
- 3GA Donnan, SM Davis, BR Chambers e mais 1. Surgery for prevention of stroke. Lancet, 1998quem mais cita →
- 4J Biller, WM Feinberg e JE Castaldo. Guidelines for carotid endarterectomy: a statement for healthcare professionals from a special writing group of the stroke council, American Heart Association. Circulation, 1998quem mais cita →
- 5North American Symptomatic Carotid Endarterectomy Trial Collaborators. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med, 1991quem mais cita →
- 6European Carotid Surgery Trialists' Collaborative Group. MRC European carotid surgery trial: interim results for symptomatic patients with severe (70-99%) or mild (0-29%) carotid stenosis. Lancet, 1991quem mais cita →
- 7European Carotid Surgery Trialists' Collaborative Group. Randomized trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST). Lancet, 1998quem mais cita →
- 8HJM Barnett, DW Taylor e M Eliasziw. benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis. N Engl J Med, 1998quem mais cita →
- 9PM Rothwell, RJ Gibson, J Slattery e mais 2. Equivalence of measurements of carotid stenosis: a comparison of three methods on 1001 angiograms. Stroke, 1994quem mais cita →
- 10CF Bladin, AV Alexandrov, J Murphy e mais 2. Carotid stenosis index: a new method of measuring internal carotid artery stenosis. Stroke, 1995quem mais cita →
- 11PM Rothwell, RJ Gibson, J Slattery e mais 1. Prognostic value and reproducibility of measurements of carotid stenosis: a comparison of three methods on 1001 angiograms. Stroke, 1994quem mais cita →
- 12GR Young, PRD Humphrey, MDM Shaw e mais 2. Comparison of magnetic resonance angiography, duplex ultrasound, and digital subtraction angiography in assessment of extracranial internal carotid artery stenosis. J Neurol Neurosurg Psychiatry, 1994quem mais cita →
- 13MO Py, C André, RC Domingues e mais 2. Internal carotid artery stenosis: comparison of duplex scan and magnetic resonance angiography with digital subtraction angiography. Arq Neuropsiquiatr, 2001no acervo →
- 14J Rankin. Cerebral vascular accidents in patients over the age of 60. Scott Med J, 1957quem mais cita →
- 15JM Bland e DG Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1986quem mais cita →
- 16LM Koran. The reliability of clinical methods, data and judgments (first of two parts). N Engl J Med, 1975quem mais cita →
- 17LM Koran. The reliability of clinical methods, data and judgments (second of two parts). N Engl J Med, 1975quem mais cita →
- 18JR Landis e GG Koch. The measurement of observer agreement for categorical data. Biometrics, 1977quem mais cita →
- 19M Eliasziw, AJ Fox, BL Sharpe e mais 1. Carotid artery stenosis: external validity of the North American Symptomatic Carotid Endarterectomy Trial measurement method. Radiology, 1997quem mais cita →
- 20LB Morgenstern, AJ Fox, BL Sharpe e mais 3. The risks and benefits of carotid endarterectomy in patients with near occlusion of the carotid artery. Neurology, 1997quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda