Arquivos de Gastroenterologia2018

NORMATIVE VALUES FOR A NEW WATER-PERFUSED HIGH RESOLUTION MANOMETRY SYSTEM

Rogério Mariotto Bitetti da SILVA, Fernando A M HERBELLA e Daniel GUALBERTO

em inglês

citado por 2 artigoscita 17 obras, 1 no acervo

resumo

ABSTRACT BACKGROUND: Esophageal manometry is the most reliable method to evaluate esophageal motility. High resolution manometry (HRM) provides topographic contour colored plots (Clouse Plots) with simultaneous analysis from the pharynx to the stomach. Both solid state and water-perfused systems are available. OBJECTIVE: This study aims to determinate the normative data for a new water-perfused HRM. METHODS: HRM was made in 32 healthy volunteers after 8 hours fasting. HRM system used consisted of a 24-channel water-perfused catheter (Multiplex, Alacer Biomedica, São Paulo, Brazil). The reusable catheter is made of polyvinyl chloride (PVC) with 4.7 mm of diameter. Side holes connected to pressure transducers are spaced 2 cm for the analysis from the pharynx to the lower esophageal sphincter (LES). Holes are spaced 5 mm and 120° in a spiral disposition in the LES area. The sensors encompass 34 cm in total. Upper esophageal sphincter (UES) parameters studied were basal and relaxation pressures. Esophageal body parameters were distal contractile integral (DCI), distal latency (DL) and break. LES parameters studied were basal pressure, integrated residual pressure (IRP), total and abdominal length. Variables are expressed as mean ± standard deviation, median (interquartile range) and percentiles 5-95th. RESULTS: All volunteers (17 males, aged 22-62 years) completed the study and tolerated the HRM procedure well. Percentiles 5-95th range were calculated: Upper Esophageal Sphincter (UES) basal pressure 16.7-184.37 (mmHg), DL: 6.2-9.1 (s), DCI: 82.72-3836.61 (mmHg.s.cm), break: <7.19 (cm), LES basal pressure: 4.89-37.16 (mmHg), IRP: 0.55-15.45 (mmHg). CONCLUSION: The performance and normative values obtained for this low-cost water-perfused HRM seems to be adequate for clinical use.

como citar · ABNT NBR 6023

SILVA, Rogério Mariotto Bitetti da; HERBELLA, Fernando A M; GUALBERTO, Daniel. NORMATIVE VALUES FOR A NEW WATER-PERFUSED HIGH RESOLUTION MANOMETRY SYSTEM. Arquivos de Gastroenterologia, 2018. DOI: 10.1590/S0004-2803.201800000-40.

Referências

17 obras citadas · 1 no acervo

  1. 1BA Jobe, JE Richter, T Hoppo e mais 3. Preoperative diagnostic workup before antireflux surgery: an evidence and experience based consensus of the Esophageal Diagnostic Advisory Panel. J Am Coll Surg, 2013quem mais cita →
  2. 2TV Herregods, S Roman, PJ Kahrilas e mais 2. Normative values in esophageal high-resolution manometry. Neurogastroenterol Motil, 2015quem mais cita →
  3. 3F Schlottmann, FA Herbella e MG Patti. Understanding the Chicago Classification: From Tracings to Patients. J Neurogastroenterol Motil, 2017quem mais cita →
  4. 4AJ Smout. Manometry of the gastrointestinal tract: toy or tool?. Scand J Gastroenterol Suppl, 2001quem mais cita →
  5. 5BF Kessing, PW Weijenborg, AJ Smout e mais 2. Water-perfused esophageal high-resolution manometry: normal values and validation. Am J Physiol Gastrointest Liver Physiol, 2014quem mais cita →
  6. 6PJ Kahrilas, AJ Bredenoord, M Fox e mais 3. The Chicago Classification of esophageal motility disorders, v3.0. Neurogastroenterol Motil, 2015quem mais cita →
  7. 7R Salvador, A Dubecz, M Polomsky e mais 3. A New Era in Esophageal Diagnostics: The Image-Based Paradigm of High-Resolution Manometry. J Am Coll Surg, 2009quem mais cita →
  8. 8LC Silva, FA Herbella, LR Neves e mais 3. Anatomophysiology of the Pharyngo-Upper Esophageal Area in Light of High-Resolution Manometry. J Gastrointest Surg, 2013quem mais cita →
  9. 9P Gehwolf, RA Hinder, KR DeVault e mais 3. Significant pressure differences between solid-state and water-perfused systems in lower esophageal sphincter measurement. Surg Endosc, 2015quem mais cita →
  10. 10D Burgos-Santamaría, A Marinero, CM Chavarría-Herbozo e mais 3. Normal values for waterperfused esophageal high-resolution manometry. Rev Esp Enferm Dig, 2015quem mais cita →
  11. 11G Capovilla, E Savarino, M Costantini e mais 3. Inter-rater and interdevice agreement for the diagnosis of primary esophageal motility disorders based on Chicago Classification between SolidState and Water-Perfused HRM System- A Prospective, Randomized, Double Blind, Crossover Study. Gastroenterology, 2014quem mais cita →
  12. 12PH Tseng, RKM Wong, JF Wu e mais 3. Normative values and factors affecting water-perfused esophageal high-resolution impedance manometry for a Chinese population. Neurogastroenterol Motil, 2018quem mais cita →
  13. 13MP Sweet, FAM Herbella, L Leard e mais 3. The prevalence of distal and proximal gastroesophageal reflux in patients awaiting lung transplantation. Ann Surg, 2006quem mais cita →
  14. 14FA Herbella e MG Patti. Can high resolution manometry parameters for achalasia be obtained by conventional manometry?.. World J Gastrointest Pathophysiol, 2015quem mais cita →
  15. 15JP Meyer, CA Jones, CC Walczak e mais 1. Three-dimensional manometry of the upper esophageal sphincter in swallowing and nonswallowing tasks. Laryngoscope, 2016quem mais cita →
  16. 16FM. Lafraia, FAM. Herbella, JR. Kalluf e mais 1. A pictorial presentation of esophageal high resolution manometry current parameters. Arq Bras Cir Dig, 2017no acervo →
  17. 17PO Katz, JE Richter, R Cowan e mais 1. Apparent Complete Lower Esophageal Sphincter Relaxation in Achalasia. Gastroenterology, 1986quem mais cita →

Quem cita esta obra

2 artigos do acervo

ano a anomais citada em 2020 · 1 artigo
Mais citada em 2020, com 1 artigo.
  • 2020: citada em 1 artigo
  • 2024: citada em 1 artigo

quem fala desta obra

17 pessoas
ver as 17 pessoas e os artigos →

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações