Arquivos Brasileiros de Oftalmologia2026
Agreement between structural parameters provided by the swept-source OCT and Laguna ONhE
Gilvan Vilarinho da Silva Filho, Gustavo Coelho Caiado, Olívia Moura de Paula Ricardo, Sergio Henrique Teixeira, Tiago dos Santos Prata, Carolina Pelegrini Barbosa Gracitelli e Augusto Paranhos Jr
em inglês
resumo
ABSTRACT Purpose: To evaluate the agreement between optic nerve head structural parameters obtained using swept-source optical coherence tomography and the Laguna ONhE software. Methods: This retrospective cross-sectional study included 353 eyes from healthy individuals, glaucoma suspects, ocular hypertensive patients, and patients with glaucoma. Optic nerve head parameters—including disc area, vertical and area cup-to-disc ratios, and rim volume—were measured using swept-source optical coherence tomography and Laguna ONhE. Agreement between methods was assessed using Bland–Altman analysis. A regression-based calibration model was developed for disc area measurements. Results: Laguna ONhE systematically underestimated disc area (p < 0.001) and cup-to-disc ratios (p<0.001) and overestimated rim volume (p=0.0002) compared with swept-source optical coherence tomography. After applying the calibration equation for disc area, agreement improved substantially, with no statistically significant bias (p=0.3). Conclusion: Laguna ONhE provides structural estimates comparable with those obtained with swept-source optical coherence tomography after calibration, suggesting it may serve as a practical and cost-effective alternative for glaucoma evaluation.
como citar · ABNT NBR 6023
SILVA FILHO, Gilvan Vilarinho da et al. Agreement between structural parameters provided by the swept-source OCT and Laguna ONhE. Arquivos Brasileiros de Oftalmologia, 2026. DOI: 10.5935/0004-2749.2025-0377.
Referências
28 obras citadas
- 1RN Weinreb, T Aung e FA Medeiros. The pathophysiology and treatment of glaucoma. JAMA, 2014quem mais cita →
- 2JB Jonas, GC Gusek e GO Naumann. Optic disc morphometry in chronic primary open-angle glaucoma. I. Morphometric intrapapillary characteristics. Graefes Arch Clin Exp Ophthalmol., 1988quem mais cita →
- 3J Caprioli e JM Miller. Optic disc rim area is related to disc size in normal subjects. Arch Ophthalmol., 1987quem mais cita →
- 4EM Hoffmann, LM Zangwill, JG Crowston e mais 1. Optic disk size and glaucoma. Surv Ophthalmol., 2007quem mais cita →
- 5TS Prata, S Dorairaj, L Trancoso e mais 3. Eyes with large disc cupping and normal intraocular pressure: using optical coherence tomography to discriminate those with and without glaucoma. Med Hypothesis Discov Innov Ophthalmol., 2014quem mais cita →
- 6AS Reis, GP Sharpe, H Yang e mais 3. Optic disc margin anatomy in patients with glaucoma and normal controls with spectral domain optical coherence tomography. Ophthalmology, 2012quem mais cita →
- 7J Olson, P Sharp, K Goatman e mais 3. Improving the economic value of photographic screening for optical coherence tomography-detectable macular oedema: a prospective, multicentre, UK study. Health Technol Assess., 2013quem mais cita →
- 8M Gonzalez de la Rosa, M Gonzalez-Hernandez, J Sigut e mais 3. Measuring hemoglobin levels in the optic nerve head: comparisons with other structural and functional parameters of glaucoma. Invest Ophthalmol Vis Sci., 2013quem mais cita →
- 9M Gonzalez-Hernandez, D Gonzalez-Hernandez, D Perez-Barbudo e mais 3. Fully automated colorimetric analysis of the optic nerve aided by deep learning and its association with perimetry and OCT for the study of glaucoma. J Clin Med., 2021quem mais cita →
- 10JA Rocha, DT Dias, MB Lemos e mais 3. Optic nerve head hemoglobin levels in glaucoma: a structural and functional correlation study. J Ophthalmol., 2021quem mais cita →
- 11C Mendez-Hernandez, I Rodriguez-Uña, M Gonzalez-de-la Rosa e mais 2. Glaucoma diagnostic capacity of optic nerve head haemoglobin measures compared with spectral domain OCT and HRT III confocal tomography. Acta Ophthalmol., 2016quem mais cita →
- 12LS Meneses, LR Ciarlini, G Ayub e mais 2. Discrimination between healthy eyes and those with mild glaucoma damage using hemoglobin measurements of the optic nerve head. J Glaucoma., 2022quem mais cita →
- 13JA Rocha, TC Goytacaz, MB Calzavara Lemos e mais 3. Assessment of structural progression in glaucoma through automated optic nerve head hemoglobin measurements. J Glaucoma., 2025quem mais cita →
- 14M Gonzalez-Hernandez, D Gonzalez-Hernandez, D Perez-Barbudo e mais 1. Optic disc area frequency distribution in a large sample of retinographic images. BMJ Open Ophthalmol., 2022quem mais cita →
- 15D Gonzalez-Hernandez, T Diaz-Aleman, D Perez-Barbudo e mais 3. Segmentation of the optic nerve head based on deep learning to determine its hemoglobin content in normal and glaucomatous subjects. J Clin Exp Ophthalmol., 2018quem mais cita →
- 16M Gonzalez-Hernandez, D Gonzalez-Hernandez, N Betancor-Caro e mais 3. Glaucoma incidence and progression in diabetics: the canary islands study using the laguna onhe application. J Clin Med., 2022quem mais cita →
- 17FA Medeiros, LM Zangwill, C Bowd e mais 3. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol., 2005quem mais cita →
- 18RS Ramrattan, RC Wolfs, JB Jonas e mais 2. Determinants of optic disc characteristics in a general population: the Rotterdam study. Ophthalmology, 1999quem mais cita →
- 19LS Freedman, D Midthune, RJ Carroll e mais 1. A comparison of regression calibration, moment reconstruction and imputation for adjusting for covariate measurement error in regression. Stat Med., 2008quem mais cita →
- 20SJ Kamun, C Nyakundi e R Simwa. Two sample approaches to regression calibration for measurement error correction. Int J Stat Distrib Appl., 2023quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda