Arquivos Brasileiros de Oftalmologia2020

Changes in anterior segment parameters following insertion of ExPRESS mini glaucoma implant vs. trabeculectomy

Eitan Livny, Na’ama Hammel, Michael Mimouni, Moshe Lusky, Igor Kaiserman e Irit Bahar

em inglês

cita 24 obras

resumo

ABSTRACT Purpose: To compare changes in anterior segment parameters following ExPRESS Mini Glaucoma Shunt surgery vs. trabeculectomy using the Pentacam rotating Scheimpflug camera. Methods: In this prospective, comparative study, 27 patients with glaucoma treated at the Rabin Medical Center from 2009 to 2013 were enrolled in this prospective comparative study: 19 participants (19 eyes) underwent ExPRESS shunt implantation and 12 (13 eyes) underwent trabeculectomy. Changes in anterior chamber parameters at postoperative day 1 and postoperative month 3 were evaluated on Scheimpflug images. Results: Intraocular pressure decreased significantly from baseline in both groups. The decrease in both groups was similar at postoperative month 3 (p=0.82). ExPRESS surgery caused a transient increase in posterior corneal astigmatism (p=0.008) and a transient decrease in anterior chamber depth (p=0.016) and volume (p=0.006) on postoperative day 1. At postoperative month 3, these parameters were no longer statistically significant (p=0.65, p=0.51, and p=0.57 respectively). Trabeculectomy caused a transient increase in anterior and posterior corneal astigmatism on postoperative day 1 (p=0.003 and p=0.005, respectively), which were not evident at postoperative month 3 (p=1.0 and p=1.0, respectively). At postoperative month 3, both ExPRESS and trabeculectomy showed similar changes in anterior chamber parameters. Conclusions: Both ExPRESS mini glaucoma implant and trabeculectomy significantly decreased intraocular pressure and had transient effects on anterior segment parameters, with minor differences between the methods.

como citar · ABNT NBR 6023

LIVNY, Eitan et al. Changes in anterior segment parameters following insertion of ExPRESS mini glaucoma implant vs. trabeculectomy. Arquivos Brasileiros de Oftalmologia, 2020. DOI: 10.5935/0004-2749.20200040.

Referências

24 obras citadas

  1. 1S Salim. Current variations of glaucoma filtration surgery. Curr Opin Ophthalmol, 2012quem mais cita →
  2. 2L de Jong, A Lafuma, AS Aguadé e mais 1. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol, 2011quem mais cita →
  3. 3S Wamsley, MR Moster, S Rai e mais 2. Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study. Am J Ophthalmol, 2004quem mais cita →
  4. 4SJ Garg, K Kanitkar, E Weichel e mais 1. Trauma-induced extrusion of an Ex-PRESS glaucoma shunt presenting as an intraocular foreign body. Arch Ophthalmol, 2005quem mais cita →
  5. 5E Dahan. Subconjunctival insertion of Ex-PRESS R-50 miniature glaucoma implant. J Cataract Refract Surg, 2008quem mais cita →
  6. 6D Rivier, S Roy e A Mermoud. Ex-PRESS R-50 miniature glaucoma implant insertion under the conjunctiva combined with cataract extraction. J Cataract Refract Surg, 2007quem mais cita →
  7. 7RM Stewart, JG Diamond, ED Ashmore e mais 1. Complications following ex-press glaucoma shunt implantation. Am J Ophthalmol, 2005quem mais cita →
  8. 8M Tavolato, S Babighian e A Galan. Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS). Eur J Ophthalmol, 2006quem mais cita →
  9. 9E Dahan e TR Carmichael. Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma, 2005quem mais cita →
  10. 10A Coupin, Q Li e I Riss. Ex-PRESS miniature glaucoma implant inserted under a scleral flap in open-angle glaucoma surgery: a retrospective study. J Fr Ophtalmol, 2007quem mais cita →
  11. 11D Lankaranian, MR Razeghinejad, A Prasad e mais 3. Intermediate-term results of the Ex-PRESS miniature glaucoma implant under a scleral flap in previously operated eyes. Clin Exp Ophthalmol, 2011quem mais cita →
  12. 12M Vetrugno, P Ferreri e C Sborgia. Ex-PRESS miniature glaucoma device in vitrectomized eyes. Eur J Ophthalmol, 2010quem mais cita →
  13. 13PJ Maris Jr, K Ishida e PA Netland. Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap. J Glaucoma, 2007quem mais cita →
  14. 14R Gallego-Pinazo, E López-Sánchez e J Marín-Montiel. Postoperative outcomes after combined glaucoma surgery. Comparison of ex-press miniature implant with standard trabeculectomy. Arch Soc Esp Oftalmol, 2009quem mais cita →
  15. 15EM Kanner, PA Netland, SR Sarkisian Jr e mais 1. Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery. J Glaucoma, 2009quem mais cita →
  16. 16TJ Good e MY Kahook. Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy. Am J Ophthalmol, 2011quem mais cita →
  17. 17F De Feo, A Bagnis e G Bricola. Efficacy and safety of a steel drainage device implanted under a scleral flap. Can J Ophthalmol, 2009quem mais cita →
  18. 18CE Traverso, F De Feo, A Messas-Kaplan e mais 3. Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification. Br J Ophthalmol, 2005quem mais cita →
  19. 19N Hammel, M Lusky, I Kaiserman e mais 2. Changes in anterior segment parameters after insertion of Ex-PRESS miniature glaucoma implant. J Glaucoma, 2013quem mais cita →
  20. 20AE Kolker, MA Kass e JL Rait. Trabeculectomy with releasable sutures. Arch Ophthalmol, 1994quem mais cita →
1–20 de 24 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações