Arquivos Brasileiros de Oftalmologia2016
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver
Alper Mete, Sabit Kimyon, Oğuzhan Saygılı, Alper Evişen, Can Pamukcu, Seda Çeri e Kıvanç Güngör
em inglês
resumo
ABSTRACT Purpose: To investigate the effects of the Valsalva maneuver (VM) on optic disc morphology, choroidal thickness, and anterior chamber parameters. Methods: This prospective observational study included 60 eyes of 60 healthy subjects. The anterior chamber parameters, including central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), pupil diameter (PD), axial length (AL), subfoveal and peripapillary choroidal thickness, optic disc parameters, and intraocular pressure (IOP), were measured at rest and during VM. Results: VM did not have any significant influence on AL, subfoveal and peripapillary choroidal thickness, optic disc area, rim area, cup area, cup-to-disc area ratio, vertical cup-to-disc ratio, rim volume, cup volume, and nerve head volume measurements (for all; p >0.05). IOP and PD significantly increased during VM (for both; p <0.001). VM significantly decreased CCT, ACD, ACA, and ACV values (for all; p <0.001). Moreover, the optic nerve cup volume decreased and the horizontal cup-to-disc ratio significantly increased during VM (for both; p <0.05). Conclusions: VM may cause transient changes in IOP, optic disc morphology, and anterior chamber parameters.
como citar · ABNT NBR 6023
METE, Alper et al. Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver. Arquivos Brasileiros de Oftalmologia, 2016. DOI: 10.5935/0004-2749.20160061.
Referências
26 obras citadas
- 1R Sihota, T Dada, A Aggarwal e mais 3. Does an iridotomy provide protection against narrowing of the anterior chamber angle during Valsalva maneuvre in eyes with primary angle closure. Eye, 2008quem mais cita →
- 2M Falcão, M Vieira, P Brito e mais 3. Spectral-domain optical coherence tomography of the choroid during valsalva maneuver. Am J Ophthalmol, 2012quem mais cita →
- 3G Pekel, S Acer, R Yagci e mais 2. Impact of valsalva maneuver on corneal morphology and anterior chamber parameters. Cornea, 2014quem mais cita →
- 4A Mete, S Kimyon, I Uzun e mais 1. Effects of valsalva maneuver on ocular biometric parameters: optical low-coherence reflectometry biometer study. Semin Ophthalmol, 2015quem mais cita →
- 5S Deokule, G Vizzeri, AG Boehm e mais 3. Correlation among choroidal, parapapillary, and retrobulbar vascular parameters in glaucoma. Am J Ophthalmol., 2009quem mais cita →
- 6G Fuchsjäger-Mayrl, B Wally, M Georgopoulos e mais 3. Ocular blood flow and systemic blood pressure in patients with primary open-angle glaucoma and ocular hypertension. Invest Ophthalmol Vis Sci, 2004quem mais cita →
- 7ME Nongpiur, LM Sakata, DS Friedman e mais 3. Novel association of smaller anterior chamber width with angle closure in Singaporeans. Ophthalmology, 2010quem mais cita →
- 8BS Wang, A Narayanaswamy, N Amerasinghe e mais 3. Increased iris thickness and association with primary angle closure glaucoma. Br J Ophthalmol, 2011quem mais cita →
- 9GM Vieira, HB Oliveira, DT Andrade e mais 2. Intraocular pressure variation during weight lifting. Arch Ophthalmol, 2006quem mais cita →
- 10I Yilmaz, C Altan, ED Aygit e mais 3. Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL. Clin Ophthalmol, 2014quem mais cita →
- 11U Aykan, M Erdurmus, B Yilmaz e mais 1. Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver. Graefes Arch Clin Exp Ophthalmol, 2010quem mais cita →
- 12T Dada, V Gupta, KK Deepak e mais 1. Narrowing of the anterior chamber angle during Valsalva maneuver: a possible mechanism of angle closure. Eur J Ophthalmol, 2006quem mais cita →
- 13BS Wang, L Xiao, J Liu e mais 2. Dynamic changes in anterior segment morphology during the Valsalva maneuver assessed with ultrasound biomicroscopy. Invest Ophthalmol Vis Sci, 2012quem mais cita →
- 14MM Whitacre, RA Stein e K Hassanein. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol, 1993quem mais cita →
- 15M Hata, F Hirose, A Oishi e mais 2. Changes in choroidal thickness and optical axial length accompanying intraocular pressure increase. Jpn J Ophthalmol, 2012quem mais cita →
- 16W Wang, M Zhou, W Huang e mais 3. Does acute primary angle-closure cause an increased choroidal thickness?. Invest Ophthalmol Vis Sci, 2013quem mais cita →
- 17DA Rosen e VC Johnston. Ocular pressure patterns in the Valsalva maneuver. Arch Ophthalmol, 1959quem mais cita →
- 18JW East e AB Smith. Intra-ocular pressure changes during maximal isometric contraction: does this reflect intracranial pressure or retinal venous pressure?. Neurol Res, 1999quem mais cita →
- 19JE Grunwald, J Piltz, SM Hariprasad e mais 1. Optic nerve and choroidal circulation in glaucoma. Invest Ophthalmol Vis Sci, 1998quem mais cita →
- 20HJ Kaiser, A Schoetzau, D Stümpfig e mais 1. Blood-flow velocities of the extraocular vessels in patients with high-tension and normal-tension primary open-angle glaucoma. Am J Ophthalmol, 1997quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda