Comparative study of the differences between dynamic and normal strategies with Octopus 1-2-3

R. M. O. Santos, S. Cronemberger, H. M. Vieira Filho e N. Calixto

em inglês

cita 7 obras

resumo

Purpose: To show the results of a comparative study between dynamic and normal strategies with Octopus 1-2-3. Methods: Automatic perimetry using the Octopus 1-2-3 with dynamic and normal strategies was performed on 24 glaucomatous patients (eight males and 16 females) within an average interval of six months between the two exams. All patients had previously submitted to at least one automatic perimetry with the Octopus 1-2-3. The data compared, for both eyes, were: the patient's age, number of questions, mean sensitivity (MS), mean defect (MD), loss variance (LV), short-term fluctuation (SF) and the reliability factor (RF). In the statistical analyses through the paired t test, only the visual fields with RF less than 10 were included. The level of significance was equal to 5% (p < 0.05). Results: There was no statistically significant difference between the two strategies in relation to age, LV, SF and RF. However, there was statistically significant differences in the duration of the test, number of questions, MS and MD. The dynamic strategy showed a higher diffuse sensitivity and a lower mean defect than the normal strategy. Conclusions: Our results show that the threshold values measured by the dynamic strategy were in close agreement with the values obtained using the normal strategy in patients who have, or are suspected of having, glaucoma and whose visual fields are normal or borderline. They also confirm the claimed reduction in testing time. These results also suggest that, when comparing a visual field exam performed with the dynamic strategy to one performed with a normal strategy, it is necessary to be cautious in regard to MS and MD values.

como citar · ABNT NBR 6023

SANTOS, R. M. O. et al. Comparative study of the differences between dynamic and normal strategies with Octopus 1-2-3. Arquivos Brasileiros de Oftalmologia, 1999. DOI: 10.1590/S0004-27491999000600013.

Referências

7 obras citadas

  1. 1Y Lachkar, O Barraut, A LeFrançois e mais 1. Stratégie rapide <<TOP>> en périmétrie automatisée Octopus. J Fr Ophtalmol, 1998quem mais cita →
  2. 2A Heijl. Time changes of contrast thresholds during automatic perimetry. Acta Ophthalmol, 1977quem mais cita →
  3. 3J Flammer e P Niesel. Reproducibility of perimetric study results. Klin Monatsbl Augenheilkd, 1984quem mais cita →
  4. 4C Hudson, JM Wild e O'Neill EC. Fatigue effects during a single session of automated static threshold perimetry. Invest Ophthalmol Vis Sci, 1994quem mais cita →
  5. 5J Weber e T Klimaschka. Test time and efficiency of the diynamic strategy in glaucoma perimetry. Ger J Ophthalmol, 1995quem mais cita →
  6. 6The Octopus Examination Software. 1996quem mais cita →
  7. 7M Zulauf, P Fehlmann e J Flammer. Perimetry with normal Octopus technique and Weber "dynamic" technique: Initial results with reference to reproducibility of measurements in glaucoma patients. Ophthalmologe, 1996quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações