Archivos Españoles de Urología (Ed. impresa)2006
Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience
Pedro J. Prada, German Juan, José Fernández, González-Suárez H, Álvaro Martínez, José González e Ana Alonso
em inglês
resumo
Objetive: Low dose rate (LDR) prostate brachytherapy (permanent 125I or 103Pd seeds) is an accepted treatment option for low risk prostate cancer patients. However, differences in prostate spatial location, volume and gland deformation between the images obtained during pre-planning and later on during the implant procedure prevent the pre-planned intended dose to be accurately delivered. We are reporting on a new technique based on interactive real-time dynamic intra-operative dose calculation with avoidance of post-implant CT for final dosimetry. The reasons leading us to implementing this new technique are discussed and preliminary results reported. Methods: A pre-planning TRUS for volumetric analysis is performed in all our patients prior to implantation. This TRUS accomplishes two objectives: 1) assessment of implantability of the gland, of organs at risk and anatomical considerations and 2) determination of seed activity and total number of seeds. On the day of the implant, new TRUS images from base to apex are obtained using a motorized stepper connected to the ultrasound and planning system. Each real time needle position placed on the target is identified and capture by the planning system in the true position. Once all real needle positions have been captured, dosimetry is performed intra-operatively and the physician approves the corresponding isodoses on real time. Flexible cystoscopy is then performed followed by seed placement. Each seed implanted is then identified upon withdrawing the needle using TRUS guidance. This allows real-time intra-operative dosimetric analysis, allowing for correction of under-dosed zones during implantation in an interactive dynamic manner. Peripheral loading is used. Results: We began our LDR prostate brachytherapy program on 1999. While we have treated 700 patients with LDR, the last 63 patients were treated with our real time dynamic intra-operative planning system. The median time duration for the procedure was 90 minutes. The median follow up time for these 63 patients was 20 months with a range of 10-36 months. At presentation, Stage T1c was seen in 55%, T2a in 36% and 9% as T2b. The Gleason grade was <7 in 81% of the patients. The median PSA value was 9 ng/ml (range 4.2-30). The median age was 64 years (range 47-78 years). For the real time intra-operative dosimetric analysis the following values were obtained: a median of 98% (90%-100%) for V90, of 60% (22%-76%) for V150 and 24% (9%-34%) for V200. The median intra- operative D90 obtained was 16,817 cGy with a range of 13,743 to 19,553 cGy. The median dose point calculation to the rectum maximum was 12,936 cGy and for the maximum in urethra was 21,880 cGy. For the real-time dynamic planning, the acute GU grade 1&2 toxicity was reduced from 28% and 21% to 16% and 6% respectively. Acute urinary retention was seen in 2/63 or 3% requiring a temporary post-implant bladder catheter. In addition, a decrease in chronic GU grade 1-2 toxicity was also seen
como citar · ABNT NBR 6023
PRADA, Pedro J. et al. Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience. Archivos Españoles de Urología (Ed. impresa), 2006. DOI: 10.4321/s0004-06142006000900021.
Referências
25 obras citadas
- 1C.J. METTLIN, G.P. MURPHY e C.J. McDONALD. The National cancer data base report on increase use of brachytherapy for the treatment of patients with prostate carcinoma in the USA. Cancer, 1999quem mais cita →
- 2R.W. LEE, J. MOUGHAN e J. OWEN. The 1999 Patterns of care Study of radiotherapy in localized prostatic carcinoma: A comprehensive survey of prostate brachytherapy in the United States. Cancer, 1987quem mais cita →
- 3D. ASH, A. FLYNN, J. BATTERMANN e mais 1. ESTRO/EAU/EORTC recomendations on permanent seed implantation for localizad prostate cancer. Radiotherapy and Oncology, 2000quem mais cita →
- 4J.J. BATTERMANN, T.A. BOON e A. MOERLAND. Results of permanent prostate brachytherapy, 13 years of experience at a single institution. Radiotherapy and Oncology, 2004quem mais cita →
- 5P.J. PRADA, G. JUAN e M. HEVIA. Tecnica de planificacion intraoperatoria en braquiterapia prostatica con implantes permanentes de 125I o 103Pd. Arch. Esp. Urol., 2002quem mais cita →
- 6N. SUBIR, P. LAY e R. CIEZKI. Intraoperative planning and evaluation of permanent prostate brachytherapy: Report of the American Brachytherapy Society. Int. J. Radiat. Oncol. Biol. Phys., 2001quem mais cita →
- 7H. RAGDE, J.C. BLASKO e D. SCHUMACHER. Use of transrectal ultrasound in transperineal Iodine-125 seeding for prostate cancer: methodology. J. Endourol., 1989quem mais cita →
- 8P.D. GRIMM, J.C. BLASKO e H. RAGDE. Ultrasound-guided transperineal implantation of Iodine-125 and Palladium-103 for the treatment of early stage prostate cancer-technical concepts in planning, operative technique, and evaluation. Atlas Ural. Clin. N. Am., 1994quem mais cita →
- 9J.C. BLASKO, H. RAGDE e D. SCHUMACHER. Transperineal percutaneous Iodine-125 implantation for prostatic carcinoma using transrectal ultrasound and template guidance. Endocuerietherapy Hyperthermia Oncology, 1987quem mais cita →
- 10R.A. CORMACK, C.M. TEMPANY e A.V. D’AMICO. Optimizing target - coverage by dosimetric feedback during prostate brachytherapy. Int. J. Radiat. Oncol. Biol. Phys., 2000quem mais cita →
- 11S. DOGGETT. Image registered real-time intraoperative treatment planning: Permanent seed brachytherapy. Radlother. Oncol., 2000quem mais cita →
- 12M.J. ZELEFSKY, J. YAMADA e G. COHEN. Postimplantation dosimetric analysis of permanent transperineal prostate implantation: Improved dose distributions with an intraoperative computer optimized conformal planning technique. Int. J. Radiat. Oncol. Biol. Phys., 2000quem mais cita →
- 13A. WU, C.C. LEE e M. JOHNSON. A new power law for determination of total 125I seed activity for ultrasound-guided prostate implants: clinical evaluations. Int. J. Radiat. Oncol. Biol. Phys., 2000quem mais cita →
- 14S. NAG, W. BICE e K. DE WYNGAERT. The American Brachytherapy Society recommendations for permanent prostate brachytherapy post-implant dosimetric analysis. Int. J. Radiat. Oncol. Biol. Phys., 2000quem mais cita →
- 15G.K. EDMUNDSON, D. YAN e A.A. MARTINEZ. Intraoperative optimization of needle placement and dwell times for conformal prostate brachytherapy. Int. J. Radiat. Oncol. Biol. Phys., 1995quem mais cita →
- 16J. STROMBERG, A. MARTINEZ e J. GONZÁLEZ. Ultrasound-guided high dose rate conformal brachytherapy boost in prostate cancer: Treatment description and preliminary results of a phase I/II clinical trial. Int. J. Radiat. Oncol. Biol. Phys., 1995quem mais cita →
- 17G. KOVACS, R. GALALAE e B. WIRTH. Optimization of interstitial brachytherapy for locally advanced prostate cancer by a new implantation technique. Strahlenther Onco., 1995quem mais cita →
- 18A. MARTINEZ, I. PATAKI e G. EDMUNDSON. Phase II prospecive study of the use of conformal high dose rate brachytherapy as monotherapy for the treatment of favorable stage prostate cancer. Int. J. Radiat. Oncol. Biol. Phys., 2001quem mais cita →
- 19R.M. GEWANTER, C.S. WUU e J.L. LAGUNA. Intraoperative preplanning for transperineal ultrasound-guided permanent prostate brachytherapy. Int. J. Radiat. Oncol. Biol. Phys., 2000quem mais cita →
- 20A. WILKINSON, E.J. LEE e J.P. CIEZKI. Dosimetric comparison of pre-planned and or-planned prostate seed brachytherapy. Int. J. Radiat. Oncol. Biol. Phys., 2000quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda