Anais da Academia Brasileira de Ciências2023
Comparative study between 1-way and 2-way coupled fluid-structure interaction in numerical simulation of aortic arch aneurysms
MÁRIO LUIS F. DA SILVA, SAULO DE FREITAS GONÇALVES, JONATHAS HANIEL, THABATA C. LUCAS e RUDOLF HUEBNER
em inglês
resumo
Abstract Hemodynamic forces are related to pathological variations of the cardiovascular system, and numerical simulations for fluid-structure interaction have been systematically used to analyze the behavior of blood flow and the arterial wall in aortic aneurysms. This paper proposes a comparative analysis of 1-way and 2-way coupled fluid-structure interaction for aortic arch aneurysm. The coupling models of fluid-structure interaction were conducted using 3D geometry of the thoracic aorta from computed tomography. Hyperelastic anisotropic properties were estimated for the Holzapfel arterial wall model. The rheological behavior of the blood was modeled by the Carreau-Yasuda model. The results showed that the 1-way approach tends to underestimate von Mises stress, displacement, and strain over the entire cardiac cycle, compared to the 2-way approach. In contrast, the behavior of the variables of flow field, velocity, wall shear stress, and Reynolds number when coupled by the 1-way model was overestimated at the systolic moment and tends to be equal at the diastolic moment. The quantitative differences found, especially during the systole, suggest the use of 2-way coupling in numerical simulations of aortic arch aneurysms due to the hyperelastic nature of the arterial wall, which leads to a strong iteration between the fluid and the arterial wall.
como citar · ABNT NBR 6023
SILVA, MÁRIO LUIS F. DA et al. Comparative study between 1-way and 2-way coupled fluid-structure interaction in numerical simulation of aortic arch aneurysms. Anais da Academia Brasileira de Ciências, 2023. DOI: 10.1590/0001-3765202320210859.
Referências
49 obras citadas
- 1J ALASTRUEY, N XIAO, H FOK e mais 2. On the Impact of Modelling Assumptions in Multi-Scale, Subject-Specific Models of Aortic Haemodynamics. Journal of The Royal Society Interface, 2016quem mais cita →
- 2PC ASME. Standard for Verification and Validation in Computational Fluid Dynamics and Heat Transfer: ASME v&v 20-2009. 2009quem mais cita →
- 3A BOCCADIFUOCO, A MARIOTTI, K CAPELLINI e mais 2. Validation of Numerical Simulations of Thoracic Aorta Hemodynamics: Comparison with in Vivo Measurements and Stochastic Sensitivity Analysis. Cardiovascular Engineering and Technology, 2018quem mais cita →
- 4AJ BOYD, DC KUHN, RJ LOZOWY e mais 1. Low Wall Shear Stress Predominates at Sites of Abdominal Aortic Aneurysm Rupture. Journal of Vascular Surgery, 2016quem mais cita →
- 5R CAMPOBASSO, F CONDEMI, M VIALLON e mais 3. Evaluation of Peak Wall Stress in an Ascending Thoracic Aortic Aneurysm Using FSI Simulations: Effects of Aortic Stiffness and Peripheral Resistance. Cardiovascular Engineering and Technology, 2018quem mais cita →
- 6S CHANDRA, SS RAUT, A JANA e mais 4. Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms: The Impact of Patient-Specific Inflow Conditions and Fluid/Solid Coupling. Journal of Biomechanical Engineering, 2013quem mais cita →
- 7YI CHO e KR KENSEY. Effects of the Non-Newtonian Viscosity of Blood on Flows in a Diseased Arterial Vessel. Part 1: Steady Flows. Biorheology, 1991quem mais cita →
- 8F COSENTINO, V AGNESE, GM RAFFA e mais 5. On the Role of Material Properties in Ascending Thoracic Aortic Aneurysms. Computers in Biology and Medicine, 2019quem mais cita →
- 9M CZERNY. Current Options and Recommendations for the Treatment of Thoracic Aortic Pathologies Involving the Aortic Arch: An Expert Consensus Document of the European Association for Cardio-Thoracic Surgery (EACTS) and the European Society for Vascular Surgery (ESVS). European Journal of Cardio-Thoracic Surgery, 2019quem mais cita →
- 10EM VAN DISSELDORP, JJ VAN DRONKELAAR, JP PLUIM e mais 3. Ultrasound Based Wall Stress Analysis of Abdominal Aortic Aneurysms Using Multiperspective Imaging. European Journal of Vascular and Endovascular Surgery, 2020quem mais cita →
- 11M ETLI, G CANBOLAT, O KARAHAN e mais 1. Numerical Investigation of Patient-Specific Thoracic Aortic Aneurysms and Comparison with Normal Subject via Computational Fluid Dynamics (CFD). Medical & Biological Engineering & Computing, 2021quem mais cita →
- 12SR DE GALARRETA, A CAZÓN, R ANTÓN e mais 1. The Relationship Between Surface Curvature and Abdominal Aortic Aneurysm Wall Stress. Journal of Biomechanical Engineering, 2017quem mais cita →
- 13CM GARCÍA-HERRERA e DJ CELENTANO. Modelling and Numerical Simulation of the Human Aortic Arch Under in Vivo Conditions. Biomechanics and Modeling in Mechanobiology, 2013quem mais cita →
- 14L GERONZI, E GASPAROTTI, K CAPELLINI e mais 6. High Fidelity Fluid-Structure Interaction by Radial Basis Functions Mesh Adaption of Moving Walls: A Workflow Applied to an Aortic Valve. Journal of Computational Science, 2021quem mais cita →
- 15H HA, M ZIEGLER, M WELANDER e mais 6. Age-Related Vascular Changes Affect Turbulence in Aortic Blood Flow. Frontiers in Physiology, 2018quem mais cita →
- 16M HIRSCHHORN, V TCHANTCHALEISHVILI, R STEVENS e mais 2. Fluid–Structure Interaction Modeling in Cardiovascular Medicine–a Systematic Review 2017–2019. Medical Engineering & Physics, 2020quem mais cita →
- 17GA HOLZAPFEL, TC GASSER e RW OGDEN. A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models. Journal of Elasticity and the Physical Science of Solids, 2000quem mais cita →
- 18U HUH, C-W LEE, J-H YOU e mais 3. Determination of the Material Parameters in the Holzapfel-Gasser-Ogden Constitutive Model for Simulation of Age-Dependent Material Nonlinear Behavior for Aortic Wall Tissue Under Uniaxial Tension. Applied Sciences, 2019quem mais cita →
- 19A KHE, A CHEREVKO, A CHUPAKHIN e mais 3. Haemodynamics of Giant Cerebral Aneurysm: A Comparison Between the Rigid-Wall, One-Way and Two-Way FSI Models. Journal of Physics: Conference Series, 2016quem mais cita →
- 20AG KUCHUMOV, V VEDENEEV, V SAMARTSEV e mais 2. Patient-Specific Fluid–Structure Interaction Model of Bile Flow: Comparison Between 1-Way and 2-Way Algorithms. Computer Methods in Biomechanics and Biomedical Engineering, 2021quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda