Anais da Academia Brasileira de Ciências2022
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling
RAFAELLA R. ANDRADE, ILDA DE FÁTIMA F. TINÔCO, FLÁVIO A. DAMASCENO, GABRIEL A.S. FERRAZ, LETÍCIA CIBELE S.R. FREITAS, CECÍLIA DE FÁTIMA S. FERREIRA, MATTEO BARBARI e CARLOS G.S. TELES JUNIOR
em inglês
citado por 1 artigocita 48 obras, 11 no acervo
resumo
Abstract In this study, we aimed to assess the spatial variability of microclimate inside a closed compost-bedded pack barn (CBP) with a negative ventilation system during summer and winter. The research was carried out in a CBP located in the Zona da Mata region, Minas Gerais, Brazil. For each of the stations analyzed, the following environmental mean variables observed inside a CBP were measured: air dry-bulb temperature (t db ), air relative humidity (RH), and windspeed, Temperature-Humidity index, and specific enthalpy. The kriging maps showed that the most critical housing conditions in the thermal environment were found, mainly, from the central part of the CBP, close to the exhaust fans. The analyses also pointed out that the system presented temperature gradients along the length, up to 3°C. During the summer afternoon, the entire region of the CBP was in a discomfort situation (t db >26°C; RH>75%). During the winter, the measured environmental data remained within the comfort zone throughout the facility. However, probably due to the lack of thermal insulation of the material used to close the sides of the CBP, it did not allow spatial thermal uniformity for both seasons. It was also inefficient to keep the animals within the comfort zone for lactating cattle during the critical summer period.
como citar · ABNT NBR 6023
ANDRADE, RAFAELLA R. et al. Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling. Anais da Academia Brasileira de Ciências, 2022. DOI: 10.1590/0001-3765202220210226.
Referências
48 obras citadas · 11 no acervo
- 1PGD ABREU, OAD COSTA, V FEDDERN e mais 3. Geostatistics applied to swine facilities equipped with evaporative cooling system. Rev Bras Eng Agric Amb, 2016no acervo →
- 2CA ALVARES, JL STAPE, PC SENTELHAS e mais 2. Köppen’s climate classification map for Brazil. Meteorol Zeitsc, 2013quem mais cita →
- 3RR ANDRADE, IFF TINÔCO, FA DAMASCENO e mais 6. Lighting and noise levels in compost dairy barns with natural and forced ventilation. Agron Res, 2020quem mais cita →
- 4RR ANDRADE, IFF TINÔCO, FA DAMASCENO e mais 5. Spatial distribution of bed variables, animal welfare indicators, and milk production in a closed compost-bedded pack barn with a negative tunnel ventilation system. J Therm Biol105, 2021quem mais cita →
- 5FC BAÊTA e CF SOUZA. Ambiência em edificações rurais: conforto ambiental. 2010quem mais cita →
- 6A BARBERG, MI ENDRES e KA JANNI. Compost dairy barns in Minnesota: A descriptive study. Appl Eng Agric, 2007quem mais cita →
- 7CA CAMBARDELLA, TB MOORMAN, JM NOVAK e mais 4. Field-scale variability of soil properties in central Iowa soils. Soil Sci Soc Am J, 1994quem mais cita →
- 8TMRC CURI, D CONTI, RA VERCELLINO e mais 4. Positioning of sensors for control of ventilation systems in broiler houses: a case study. Scient Agric, 2017no acervo →
- 9FA DAMASCENO. Compost Barn como alternativa para a pecuária leiteira. 2020quem mais cita →
- 10FA DAMASCENO, CEA OLIVEIRA, GAS FERRAZ e mais 3. Spatial distribution of thermal variables, acoustics and lighting in compost dairy barn with climate control system. Agron Res, 2019quem mais cita →
- 11S DIKMEN, CC LARSON, A DE VRIES e mais 1. Effectiveness of tunnel ventilation as dairy cow housing in hot climates: rectal temperatures during heat stress and seasonal variation in milk yield. Trop An Health Prod, 2020quem mais cita →
- 12FF FARIA, DJ MOURA, ZMD SOUZA e mais 1. Variabilidade espacial do microclima de um galpão utilizado para confinamento de bovinos de leite. Ciência Rural, 2008no acervo →
- 13PF FERRAZ, T YANAGI, L SCHIASSI e mais 2. Spatial variability of enthalpy in broiler house during the heating phase. Rev Bras Eng Agric Amb, 2016no acervo →
- 14LCSR FREITAS, IFF TINÔCO, RS GATES e mais 2. Spatial behavior of the thermo-luminous conditions of facility laying hens in naturally ventilated vertical system. Ciênc Agrotecnol, 2018no acervo →
- 15LCSR FREITAS, IFF TINÔCO, RS GATES e mais 3. Development and validation of a data logger for thermal characterization in laying hen facilities. Rev Bras Eng Agric Amb, 2019no acervo →
- 16S FOURNEL, V OUELLET e É CHARBONNEAU. Practices for alleviating heat stress of dairy cows in humid continental climates: a literature review. Animals, 2017quem mais cita →
- 17PR GARCIA. Galpão freestall com sistema de resfriamento evaporativo e ventilação cruzada: desempenho térmico, zootécnico e o nível de bem-estar animal. 2017quem mais cita →
- 18JP HARNER e JF SMITH. Low-profile cross-ventilated freestall facilities-A 2 year summary. 2008quem mais cita →
- 19KA JANNI, MI ENDRES, JK RENEAU e mais 1. Compost dairy barn layout and management recommendations. Appl Eng Agric, 2007quem mais cita →
- 20CT KADZERE, MR MURPHY, N SILANIKOVE e mais 1. Heat stress in lactating dairy cows: A review. Livestock Prod Sci, 2002quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
10 pessoas- RAFAELLA R. ANDRADEautocitação1 artigo · 2023
- FLÁVIO A. DAMASCENOautocitação1 artigo · 2023
- GABRIEL A.S. FERRAZautocitação1 artigo · 2023
- JOÃO ANTÔNIO C. DO NASCIMENTO1 artigo · 2023
- CARLOS EDUARDO A. OLIVEIRA1 artigo · 2023
- VICTOR C. DE OLIVEIRA1 artigo · 2023
- PEDRO HENRIQUE M. RODRIGUES1 artigo · 2023
- LEONARDO F. DA SILVA1 artigo · 2023
- FERNANDA C. DE SOUSA1 artigo · 2023
- ILDA DE FÁTIMA F. TINÔCOautocitação1 artigo · 2023
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda